FabDigitFabDigit

Aluminum 6011-O vs 6011-T6

Aluminum · 6011 temper comparison

6011-O and 6011-T6 are two conditions of the same aluminum grade, 6011: O (annealed) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 6011-T6 is the stronger of the two: yield strength 330 MPa (47.9 ksi) against 70 MPa (10.2 ksi) for 6011-O, about 4.7 times as much; tensile strength follows at 380 MPa (55.1 ksi) vs 150 MPa (21.8 ksi). In exchange, 6011-O is the more ductile: elongation 25% versus 12% for 6011-T6, and 6011-T6 is harder (110 HB vs 40 HB). 6011-O conducts heat better (185 W/m·K vs 165 W/m·K). On the shop floor, 6011-T6 machines more easily (very good vs fair).

6011-OChoose it when the part is bent, formed or impact-loaded.

6011-T6Choose it when strength drives the design, or when the part is machined in volume.

6011-O vs 6011-T6: properties

6011-O6011-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

150 MPa21.8 ksi
380 MPa55.1 ksi

Yield Strength (0.2% offset)

70 MPa10.2 ksi
330 MPa47.9 ksi

Elongation at Break

25%
12%

Shear Strength

100 MPa14.5 ksi
230 MPa33.4 ksi

Hardness, Brinell

40 HB
110 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33 · Fatigue Strength (Endurance Limit) 105 MPa15.2 ksi · Fracture Toughness (K_IC) 30 MPa·√m27.3 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 2.72 g/cm³0.1 lb/in³ · Melting Point (Solidus) 585°C1,085 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

185 W/m·K107 BTU/hr·ft·°F
165 W/m·K95.3 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 896 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

48 % IACS
42 % IACS

Same in both: Electrical Resistivity 4.1×10⁻⁸ Ω·m1.61 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

58 / 100
55 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.77 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
82 / 100

Weldability

50 / 100
45 / 100

Formability (cold)

85 / 100
45 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 190% · Brazeability / Solderability 35 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6011

6011-O vs 6011-T6 — frequently asked

Is 6011-T6 stronger than 6011-O?

Yes. 6011-T6 has a typical yield strength of 330 MPa (47.9 ksi) against 70 MPa (10.2 ksi) for 6011-O — about 4.7 times as much. Tensile strength is 380 MPa (55.1 ksi) vs 150 MPa (21.8 ksi).

Which condition does FabDigit quote by default, O or T6?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 6011-O or 6011-T6?

6011-T6. Its machinability rates very good (82/100) against fair (45/100) for 6011-O; for welding the order is 6011-O first (fair, 50/100) then 6011-T6 (fair, 45/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6011-O and 6011-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.