FabDigitFabDigit

Aluminum 6005-O vs 6005-T5

Aluminum · 6005 temper comparison

6005-O and 6005-T5 are two conditions of the same aluminum grade, 6005: O (annealed) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. 6005-T5 is the stronger of the two: yield strength 245 MPa (35.5 ksi) against 60 MPa (8.7 ksi) for 6005-O, about 4.1 times as much; tensile strength follows at 270 MPa (39.2 ksi) vs 125 MPa (18.1 ksi). In exchange, 6005-O is the more ductile: elongation 26% versus 11% for 6005-T5, and 6005-T5 is harder (85 HB vs 30 HB). 6005-O runs hotter in service (200°C vs 150°C continuous). On the shop floor, 6005-T5 machines more easily (good vs fair).

6005-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

6005-T5Choose it when strength drives the design, or when the part is machined in volume.

6005-O vs 6005-T5: properties

6005-O6005-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

125 MPa18.1 ksi
270 MPa39.2 ksi

Yield Strength (0.2% offset)

60 MPa8.7 ksi
245 MPa35.5 ksi

Elongation at Break

26%
11%

Shear Strength

83 MPa12 ksi
172 MPa24.9 ksi

Fatigue Strength (Endurance Limit)

55 MPa8 ksi
90 MPa13.1 ksi

Hardness, Brinell

30 HB
85 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33 · Fracture Toughness (K_IC) 30 MPa·√m27.3 ksi·√in · Hardness, Vickers 90 HV

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 607°C1,125 °F · Liquidus Temperature 654°C1,209 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

200 W/m·K116 BTU/hr·ft·°F
188 W/m·K109 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
150°C302 °F

Same in both: Specific Heat Capacity 897 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

52 % IACS
49 % IACS

Electrical Resistivity

3.32×10⁻⁸ Ω·m1.31 µΩ·in
3.52×10⁻⁸ Ω·m1.39 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
55 / 100

Formability (cold)

88 / 100
40 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 50% · Weldability 80 / 100 · Brazeability / Solderability 50 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6005

6005-O vs 6005-T5 — frequently asked

Is 6005-T5 stronger than 6005-O?

Yes. 6005-T5 has a typical yield strength of 245 MPa (35.5 ksi) against 60 MPa (8.7 ksi) for 6005-O — about 4.1 times as much. Tensile strength is 270 MPa (39.2 ksi) vs 125 MPa (18.1 ksi).

Which condition does FabDigit quote by default, O or T5?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 6005-O or 6005-T5?

6005-T5. Its machinability rates good (55/100) against fair (35/100) for 6005-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6005-O and 6005-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.