FabDigitFabDigit

Aluminum 5A05-H112 vs 5A05-H14

Aluminum · 5A05 temper comparison

5A05-H112 and 5A05-H14 are two conditions of the same aluminum grade, 5A05: H112 (strain hardened from hot working only) versus H14 (strain hardened, half hard). The chemistry is identical, so every difference below comes from the condition. 5A05-H14 is the stronger of the two: yield strength 270 MPa (39.2 ksi) against 150 MPa (21.8 ksi) for 5A05-H112, about 80% more; tensile strength follows at 340 MPa (49.3 ksi) vs 275 MPa (39.9 ksi). In exchange, 5A05-H112 is the more ductile: elongation 16% versus 7% for 5A05-H14, and 5A05-H14 is harder (95 HB vs 72 HB). 5A05-H112 runs hotter in service (65°C vs 55°C continuous). On the shop floor, 5A05-H14 machines more easily (good vs fair).

5A05-H112Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5A05-H14Choose it when strength drives the design, or when the part is machined in volume.

5A05-H112 vs 5A05-H14: properties

5A05-H1125A05-H14

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

275 MPa39.9 ksi
340 MPa49.3 ksi

Yield Strength (0.2% offset)

150 MPa21.8 ksi
270 MPa39.2 ksi

Elongation at Break

16%
7%

Shear Strength

178 MPa25.8 ksi
205 MPa29.7 ksi

Fatigue Strength (Endurance Limit)

132 MPa19.1 ksi
150 MPa21.8 ksi

Fracture Toughness (K_IC)

35 MPa·√m31.9 ksi·√in
28 MPa·√m25.5 ksi·√in

Hardness, Brinell

72 HB
95 HB

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.65 g/cm³0.1 lb/in³ · Melting Point (Solidus) 568°C1,054 °F · Liquidus Temperature 638°C1,180 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

117 W/m·K67.6 BTU/hr·ft·°F
116 W/m·K67 BTU/hr·ft·°F

Max Service Temperature (continuous)

65°C149 °F
55°C131 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.8 µm/m·K13.2 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

29 % IACS
28.5 % IACS

Electrical Resistivity

5.9×10⁻⁸ Ω·m2.32 µΩ·in
6.05×10⁻⁸ Ω·m2.38 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

74 / 100
68 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.87 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

33%
40%

Weldability

90 / 100
82 / 100

Formability (cold)

70 / 100
45 / 100

Same in both: Brazeability / Solderability 20 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5A05

5A05-H112 vs 5A05-H14 — frequently asked

Is 5A05-H14 stronger than 5A05-H112?

Yes. 5A05-H14 has a typical yield strength of 270 MPa (39.2 ksi) against 150 MPa (21.8 ksi) for 5A05-H112 — about 80% more. Tensile strength is 340 MPa (49.3 ksi) vs 275 MPa (39.9 ksi).

Which condition does FabDigit quote by default, H112 or H14?

O is the default 5A05 condition in the FabDigit quote flow (neither H112 nor H14). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5A05-H112 or 5A05-H14?

5A05-H14. Its machinability rates good (55/100) against fair (45/100) for 5A05-H112; for welding the order is 5A05-H112 first (excellent, 90/100) then 5A05-H14 (very good, 82/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5A05-H112 and 5A05-H14 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.