FabDigitFabDigit

Aluminum 5A05-F vs 5A05-H34

Aluminum · 5A05 temper comparison

5A05-F and 5A05-H34 are two conditions of the same aluminum grade, 5A05: F (as fabricated) versus H34 (strain hardened and stabilized, half hard). The chemistry is identical, so every difference below comes from the condition. 5A05-H34 is the stronger of the two: yield strength 250 MPa (36.3 ksi) against 145 MPa (21 ksi) for 5A05-F, about 72% more; tensile strength follows at 330 MPa (47.9 ksi) vs 270 MPa (39.2 ksi). In exchange, 5A05-F is the more ductile: elongation 18% versus 9% for 5A05-H34, and 5A05-H34 is harder (88 HB vs 70 HB). On the shop floor, 5A05-H34 machines more easily (52 vs 42 out of 100).

5A05-FChoose it when the part is bent, formed or impact-loaded.

5A05-H34Choose it when strength drives the design, or when the part is machined in volume.

5A05-F vs 5A05-H34: properties

5A05-F5A05-H34

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

270 MPa39.2 ksi
330 MPa47.9 ksi

Yield Strength (0.2% offset)

145 MPa21 ksi
250 MPa36.3 ksi

Elongation at Break

18%
9%

Shear Strength

175 MPa25.4 ksi
195 MPa28.3 ksi

Fatigue Strength (Endurance Limit)

130 MPa18.9 ksi
147 MPa21.3 ksi

Fracture Toughness (K_IC)

35 MPa·√m31.9 ksi·√in
30 MPa·√m27.3 ksi·√in

Hardness, Brinell

70 HB
88 HB

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.65 g/cm³0.1 lb/in³ · Melting Point (Solidus) 568°C1,054 °F · Liquidus Temperature 638°C1,180 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

117 W/m·K67.6 BTU/hr·ft·°F
116 W/m·K67 BTU/hr·ft·°F

Max Service Temperature (continuous)

65°C149 °F
60°C140 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.8 µm/m·K13.2 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 29 % IACS · Electrical Resistivity 5.9×10⁻⁸ Ω·m2.32 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

72 / 100
70 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.87 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
52 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
38%

Weldability

90 / 100
85 / 100

Formability (cold)

74 / 100
50 / 100

Same in both: Brazeability / Solderability 20 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5A05

5A05-F vs 5A05-H34 — frequently asked

Is 5A05-H34 stronger than 5A05-F?

Yes. 5A05-H34 has a typical yield strength of 250 MPa (36.3 ksi) against 145 MPa (21 ksi) for 5A05-F — about 72% more. Tensile strength is 330 MPa (47.9 ksi) vs 270 MPa (39.2 ksi).

Which condition does FabDigit quote by default, F or H34?

O is the default 5A05 condition in the FabDigit quote flow (neither F nor H34). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5A05-F or 5A05-H34?

5A05-H34, by a small margin. Both rate fair for machinability — 52/100 against 42/100 for 5A05-F; for welding the order is 5A05-F first (excellent, 90/100) then 5A05-H34 (excellent, 85/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5A05-F and 5A05-H34 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.