FabDigitFabDigit

Aluminum 5556-H14 vs 5556-O

Aluminum · 5556 temper comparison

5556-H14 and 5556-O are two conditions of the same aluminum grade, 5556: H14 (strain hardened, half hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 5556-H14 is the stronger of the two: yield strength 275 MPa (39.9 ksi) against 150 MPa (21.8 ksi) for 5556-O, about 83% more; tensile strength follows at 345 MPa (50 ksi) vs 300 MPa (43.5 ksi). In exchange, 5556-O is the more ductile: elongation 24% versus 7% for 5556-H14, and 5556-H14 is harder (88 HB vs 70 HB). On the shop floor, 5556-H14 machines more easily (50 vs 40 out of 100).

5556-H14Choose it when strength drives the design, or when the part is machined in volume.

5556-OChoose it when the part is bent, formed or impact-loaded.

5556-H14 vs 5556-O: properties

5556-H145556-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

345 MPa50 ksi
300 MPa43.5 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
150 MPa21.8 ksi

Elongation at Break

7%
24%

Shear Strength

200 MPa29 ksi
180 MPa26.1 ksi

Fatigue Strength (Endurance Limit)

125 MPa18.1 ksi
105 MPa15.2 ksi

Hardness, Brinell

88 HB
70 HB

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 26.4 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.66 g/cm³0.1 lb/in³ · Melting Point (Solidus) 568°C1,054 °F · Liquidus Temperature 638°C1,180 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

108 W/m·K62.4 BTU/hr·ft·°F
113 W/m·K65.3 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 24.2 µm/m·K13.4 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Max Service Temperature (continuous) 65°C149 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

28 % IACS
29.5 % IACS

Electrical Resistivity

6.15×10⁻⁸ Ω·m2.42 µΩ·in
5.85×10⁻⁸ Ω·m2.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

70 / 100
78 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.87 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
35%

Weldability

92 / 100
94 / 100

Formability (cold)

40 / 100
65 / 100

Same in both: Castability 35 / 100 · Brazeability / Solderability 10 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 15%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5556

5556-H14 vs 5556-O — frequently asked

Is 5556-H14 stronger than 5556-O?

Yes. 5556-H14 has a typical yield strength of 275 MPa (39.9 ksi) against 150 MPa (21.8 ksi) for 5556-O — about 83% more. Tensile strength is 345 MPa (50 ksi) vs 300 MPa (43.5 ksi).

Which condition does FabDigit quote by default, H14 or O?

AW is the default 5556 condition in the FabDigit quote flow (neither H14 nor O). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5556-H14 or 5556-O?

5556-H14, by a small margin. Both rate fair for machinability — 50/100 against 40/100 for 5556-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5556-H14 and 5556-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.