FabDigitFabDigit

Aluminum 5252-H34 vs 5252-O

Aluminum · 5252 temper comparison

5252-H34 and 5252-O are two conditions of the same aluminum grade, 5252: H34 (strain hardened and stabilized, half hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 5252-H34 is the stronger of the two: yield strength 210 MPa (30.5 ksi) against 85 MPa (12.3 ksi) for 5252-O, about 147% more; tensile strength follows at 260 MPa (37.7 ksi) vs 180 MPa (26.1 ksi). In exchange, 5252-O is the more ductile: elongation 23% versus 8% for 5252-H34, and 5252-H34 is harder (74 HB vs 47 HB). 5252-O runs hotter in service (200°C vs 130°C continuous). On the shop floor, 5252-H34 machines more easily (46 vs 35 out of 100).

5252-H34Choose it when strength drives the design, or when the part is machined in volume.

5252-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5252-H34 vs 5252-O: properties

5252-H345252-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

260 MPa37.7 ksi
180 MPa26.1 ksi

Yield Strength (0.2% offset)

210 MPa30.5 ksi
85 MPa12.3 ksi

Elongation at Break

8%
23%

Shear Strength

155 MPa22.5 ksi
120 MPa17.4 ksi

Fatigue Strength (Endurance Limit)

115 MPa16.7 ksi
85 MPa12.3 ksi

Hardness, Brinell

74 HB
47 HB

Same in both: Elastic (Young's) Modulus 68.9 GPa10 Msi · Shear Modulus 25.9 GPa3.8 Msi · Bulk Modulus 68 GPa9.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.67 g/cm³0.1 lb/in³ · Melting Point (Solidus) 607°C1,125 °F · Liquidus Temperature 654°C1,209 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

130°C266 °F
200°C392 °F

Same in both: Thermal Conductivity 138 W/m·K79.7 BTU/hr·ft·°F · Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.8 µm/m·K13.2 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 35 % IACS · Electrical Resistivity 4.93×10⁻⁸ Ω·m1.94 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

65 / 100
70 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.86 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

46 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

34%
25%

Weldability

76 / 100
80 / 100

Formability (cold)

55 / 100
88 / 100

Same in both: Brazeability / Solderability 25 / 100 · Polishability 88 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 15%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5252

5252-H34 vs 5252-O — frequently asked

Is 5252-H34 stronger than 5252-O?

Yes. 5252-H34 has a typical yield strength of 210 MPa (30.5 ksi) against 85 MPa (12.3 ksi) for 5252-O — about 147% more. Tensile strength is 260 MPa (37.7 ksi) vs 180 MPa (26.1 ksi).

Which condition does FabDigit quote by default, H34 or O?

H25 is the default 5252 condition in the FabDigit quote flow (neither H34 nor O). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5252-H34 or 5252-O?

5252-H34, by a small margin. Both rate fair for machinability — 46/100 against 35/100 for 5252-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5252-H34 and 5252-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.