Aluminum 5252-H28 vs 5252-H32

Aluminum · 5252 temper comparison

5252-H28 and 5252-H32 are two conditions of the same aluminum grade, 5252: H28 (strain hardened and partially annealed, full hard) versus H32 (strain hardened and stabilized, quarter hard). The chemistry is identical, so every difference below comes from the condition. 5252-H28 is the stronger of the two: yield strength 240 MPa (34.8 ksi) against 175 MPa (25.4 ksi) for 5252-H32, about 37% more; tensile strength follows at 285 MPa (41.3 ksi) vs 230 MPa (33.4 ksi). In exchange, 5252-H32 is the more ductile: elongation 12% versus 5% for 5252-H28, and 5252-H28 is harder (80 HB vs 66 HB). 5252-H32 runs hotter in service (150°C vs 120°C continuous).

5252-H28Choose it when strength drives the design.

5252-H32Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5252-H28 vs 5252-H32: properties

5252-H285252-H32

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

285 MPa41.3 ksi
230 MPa33.4 ksi

Yield Strength (0.2% offset)

240 MPa34.8 ksi
175 MPa25.4 ksi

Elongation at Break

5%
12%

Shear Strength

165 MPa23.9 ksi
145 MPa21 ksi

Fatigue Strength (Endurance Limit)

125 MPa18.1 ksi
110 MPa16 ksi

Hardness, Brinell

80 HB
66 HB

Same in both: Elastic (Young's) Modulus 68.9 GPa10 Msi · Shear Modulus 25.9 GPa3.8 Msi · Bulk Modulus 68 GPa9.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.67 g/cm³0.1 lb/in³ · Melting Point (Solidus) 607°C1,125 °F · Liquidus Temperature 654°C1,209 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

120°C248 °F
150°C302 °F

Same in both: Thermal Conductivity 138 W/m·K79.7 BTU/hr·ft·°F · Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.8 µm/m·K13.2 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 35 % IACS · Electrical Resistivity 4.93×10⁻⁸ Ω·m1.94 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

63 / 100
67 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.86 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

38%
30%

Weldability

74 / 100
78 / 100

Formability (cold)

45 / 100
70 / 100

Same in both: Brazeability / Solderability 25 / 100 · Polishability 88 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 15%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5252

5252-H28 vs 5252-H32 — frequently asked

Is 5252-H28 stronger than 5252-H32?

Yes. 5252-H28 has a typical yield strength of 240 MPa (34.8 ksi) against 175 MPa (25.4 ksi) for 5252-H32 — about 37% more. Tensile strength is 285 MPa (41.3 ksi) vs 230 MPa (33.4 ksi).

Which condition does FabDigit quote by default, H28 or H32?

H25 is the default 5252 condition in the FabDigit quote flow (neither H28 nor H32). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5252-H28 or 5252-H32?

5252-H28, by a small margin. Both rate fair for machinability — 50/100 against 42/100 for 5252-H32.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5252-H28 and 5252-H32 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.