5182-H111 and 5182-H18 are two conditions of the same aluminum grade, 5182: H111 (slightly strain hardened) versus H18 (strain hardened, full hard). The chemistry is identical, so every difference below comes from the condition. 5182-H18 is the stronger of the two: yield strength 385 MPa (55.8 ksi) against 150 MPa (21.8 ksi) for 5182-H111, about 157% more; tensile strength follows at 410 MPa (59.5 ksi) vs 290 MPa (42.1 ksi). In exchange, 5182-H111 is the more ductile: elongation 19% versus 4% for 5182-H18, and 5182-H18 is harder (105 HB vs 75 HB).

5182-H111Choose it when the part is bent, formed or impact-loaded.

5182-H18Choose it when strength drives the design.

5182-H111 vs 5182-H18: properties

5182-H1115182-H18

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Shear Modulus

26 GPa3.8 Msi
26.4 GPa3.8 Msi

Bulk Modulus

70 GPa10.2 Msi
69 GPa10 Msi

Tensile Strength (Ultimate)

290 MPa42.1 ksi
410 MPa59.5 ksi

Yield Strength (0.2% offset)

150 MPa21.8 ksi
385 MPa55.8 ksi

Elongation at Break

19%
4%

Shear Strength

175 MPa25.4 ksi
235 MPa34.1 ksi

Fatigue Strength (Endurance Limit)

140 MPa20.3 ksi
145 MPa21 ksi

Hardness, Brinell

75 HB
105 HB

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.65 g/cm³0.1 lb/in³ · Melting Point (Solidus) 577°C1,071 °F · Liquidus Temperature 638°C1,180 °F

Thermal

How each material carries heat and how hot it can run.

Specific Heat Capacity

900 J/kg·K0.21 BTU/lb·°F
904 J/kg·K0.22 BTU/lb·°F

Latent Heat of Fusion

390 J/g168 BTU/lb
395 J/g170 BTU/lb

Same in both: Thermal Conductivity 123 W/m·K71.1 BTU/hr·ft·°F · Thermal Expansion (CTE, 20–100 °C) 24.1 µm/m·K13.4 µin/in·°F · Max Service Temperature (continuous) 65°C149 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 31 % IACS · Electrical Resistivity 5.6×10⁻⁸ Ω·m2.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.86 V
-0.87 V

Same in both: Corrosion Resistance 72 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

38 / 100
45 / 100

Weldability

85 / 100
78 / 100

Formability (cold)

85 / 100
25 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Brazeability / Solderability 15 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

200 MJ/kg85,985 BTU/lb
155 MJ/kg66,638 BTU/lb

Embodied Carbon (primary production)

12.5 kg CO₂/kg
9.5 kg CO₂/kg

Typical Recycled Content

55%
40%

Same in both: Embodied Water 1,200 L/kg144 gal/lb

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5182

5182-H111 vs 5182-H18 — frequently asked

Is 5182-H18 stronger than 5182-H111?

Yes. 5182-H18 has a typical yield strength of 385 MPa (55.8 ksi) against 150 MPa (21.8 ksi) for 5182-H111 — about 157% more. Tensile strength is 410 MPa (59.5 ksi) vs 290 MPa (42.1 ksi).

Which condition does FabDigit quote by default, H111 or H18?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 5182-H111 or 5182-H18?

5182-H18, by a small margin. Both rate fair for machinability — 45/100 against 38/100 for 5182-H111; for welding the order is 5182-H111 first (excellent, 85/100) then 5182-H18 (very good, 78/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5182-H111 and 5182-H18 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.