FabDigitFabDigit

Aluminum 5083-H111 vs 5083-H32

Aluminum · 5083 temper comparison

5083-H111 and 5083-H32 are two conditions of the same aluminum grade, 5083: H111 (slightly strain hardened) versus H32 (strain hardened and stabilized, quarter hard). The chemistry is identical, so every difference below comes from the condition. 5083-H32 is the stronger of the two: yield strength 225 MPa (32.6 ksi) against 165 MPa (23.9 ksi) for 5083-H111, about 36% more. In exchange, 5083-H111 is the more ductile: elongation 18% versus 15% for 5083-H32, and 5083-H32 is harder (85 HB vs 70 HB).

5083-H111Choose it when the part is bent, formed or impact-loaded.

5083-H32Choose it when strength drives the design.

5083-H111 vs 5083-H32: properties

5083-H1115083-H32

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

300 MPa43.5 ksi
315 MPa45.7 ksi

Yield Strength (0.2% offset)

165 MPa23.9 ksi
225 MPa32.6 ksi

Elongation at Break

18%
15%

Shear Strength

180 MPa26.1 ksi
185 MPa26.8 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
160 MPa23.2 ksi

Fracture Toughness (K_IC)

38 MPa·√m34.6 ksi·√in
34 MPa·√m30.9 ksi·√in

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
25 J18.4 ft·lbf

Hardness, Brinell

70 HB
85 HB

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 26.4 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.66 g/cm³0.1 lb/in³ · Melting Point (Solidus) 574°C1,065 °F · Liquidus Temperature 638°C1,180 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 117 W/m·K67.6 BTU/hr·ft·°F · Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.8 µm/m·K13.2 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Max Service Temperature (continuous) 65°C149 °F · Min Service Temperature -270°C-454 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 29 % IACS · Electrical Resistivity 5.9×10⁻⁸ Ω·m2.32 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

84 / 100
80 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.87 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
30%

Weldability

92 / 100
90 / 100

Formability (cold)

78 / 100
55 / 100

Same in both: Castability 15 / 100 · Brazeability / Solderability 15 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 175 MJ/kg75,237 BTU/lb · Embodied Carbon (primary production) 11.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5083

5083-H111 vs 5083-H32 — frequently asked

Is 5083-H32 stronger than 5083-H111?

Yes. 5083-H32 has a typical yield strength of 225 MPa (32.6 ksi) against 165 MPa (23.9 ksi) for 5083-H111 — about 36% more. Tensile strength is 315 MPa (45.7 ksi) vs 300 MPa (43.5 ksi).

Which condition does FabDigit quote by default, H111 or H32?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 5083-H111 or 5083-H32?

5083-H32, by a small margin. Both rate fair for machinability — 50/100 against 45/100 for 5083-H111.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5083-H111 and 5083-H32 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.