FabDigitFabDigit

Aluminum 5056-H32 vs 5056-O

Aluminum · 5056 temper comparison

5056-H32 and 5056-O are two conditions of the same aluminum grade, 5056: H32 (strain hardened and stabilized, quarter hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 5056-H32 is the stronger of the two: yield strength 235 MPa (34.1 ksi) against 152 MPa (22 ksi) for 5056-O, about 55% more; tensile strength follows at 330 MPa (47.9 ksi) vs 290 MPa (42.1 ksi). In exchange, 5056-O is the more ductile: elongation 35% versus 20% for 5056-H32, and 5056-H32 is harder (78 HB vs 65 HB). On the shop floor, 5056-H32 machines more easily (good vs fair).

5056-H32Choose it when strength drives the design, or when the part is machined in volume.

5056-OChoose it when the part is bent, formed or impact-loaded.

5056-H32 vs 5056-O: properties

5056-H325056-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

330 MPa47.9 ksi
290 MPa42.1 ksi

Yield Strength (0.2% offset)

235 MPa34.1 ksi
152 MPa22 ksi

Elongation at Break

20%
35%

Shear Strength

195 MPa28.3 ksi
180 MPa26.1 ksi

Fatigue Strength (Endurance Limit)

145 MPa21 ksi
138 MPa20 ksi

Hardness, Brinell

78 HB
65 HB

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.64 g/cm³0.1 lb/in³ · Melting Point (Solidus) 568°C1,054 °F · Liquidus Temperature 638°C1,180 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

112 W/m·K64.7 BTU/hr·ft·°F
117 W/m·K67.6 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 904 J/kg·K0.22 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 24.1 µm/m·K13.4 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Max Service Temperature (continuous) 65°C149 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

28 % IACS
29 % IACS

Same in both: Electrical Resistivity 6.15×10⁻⁸ Ω·m2.42 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

76 / 100
78 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.87 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
45 / 100

Formability (cold)

55 / 100
85 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 40% · Weldability 85 / 100 · Brazeability / Solderability 20 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5056

5056-H32 vs 5056-O — frequently asked

Is 5056-H32 stronger than 5056-O?

Yes. 5056-H32 has a typical yield strength of 235 MPa (34.1 ksi) against 152 MPa (22 ksi) for 5056-O — about 55% more. Tensile strength is 330 MPa (47.9 ksi) vs 290 MPa (42.1 ksi).

Which condition does FabDigit quote by default, H32 or O?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 5056-H32 or 5056-O?

5056-H32. Its machinability rates good (55/100) against fair (45/100) for 5056-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5056-H32 and 5056-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.