FabDigitFabDigit

Aluminum 5052-H112 vs 5052-H32

Aluminum · 5052 temper comparison

5052-H112 and 5052-H32 are two conditions of the same aluminum grade, 5052: H112 (strain hardened from hot working only) versus H32 (strain hardened and stabilized, quarter hard). The chemistry is identical, so every difference below comes from the condition. 5052-H32 is the stronger of the two: yield strength 195 MPa (28.3 ksi) against 110 MPa (16 ksi) for 5052-H112, about 77% more; tensile strength follows at 230 MPa (33.4 ksi) vs 200 MPa (29 ksi). In exchange, 5052-H112 is the more ductile: elongation 16% versus 12% for 5052-H32, and 5052-H32 is harder (60 HB vs 50 HB). 5052-H112 runs hotter in service (175°C vs 150°C continuous).

5052-H112Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5052-H32Choose it when strength drives the design.

5052-H112 vs 5052-H32: properties

5052-H1125052-H32

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

200 MPa29 ksi
230 MPa33.4 ksi

Yield Strength (0.2% offset)

110 MPa16 ksi
195 MPa28.3 ksi

Elongation at Break

16%
12%

Shear Strength

128 MPa18.6 ksi
138 MPa20 ksi

Fatigue Strength (Endurance Limit)

110 MPa16 ksi
117 MPa17 ksi

Hardness, Brinell

50 HB
60 HB

Hardness, Vickers

55 HV
68 HV

Same in both: Elastic (Young's) Modulus 70.3 GPa10.2 Msi · Shear Modulus 25.9 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.68 g/cm³0.1 lb/in³ · Melting Point (Solidus) 607°C1,125 °F · Liquidus Temperature 649°C1,200 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

140 W/m·K80.9 BTU/hr·ft·°F
138 W/m·K79.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

175°C347 °F
150°C302 °F

Same in both: Specific Heat Capacity 880 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.8 µm/m·K13.2 µin/in·°F · Latent Heat of Fusion 393 J/g169 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 35 % IACS · Electrical Resistivity 4.93×10⁻⁸ Ω·m1.94 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

73 / 100
72 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.85 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

28%
30%

Formability (cold)

85 / 100
75 / 100

Same in both: Weldability 90 / 100 · Brazeability / Solderability 20 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 155 MJ/kg66,638 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5052

5052-H112 vs 5052-H32 — frequently asked

Is 5052-H32 stronger than 5052-H112?

Yes. 5052-H32 has a typical yield strength of 195 MPa (28.3 ksi) against 110 MPa (16 ksi) for 5052-H112 — about 77% more. Tensile strength is 230 MPa (33.4 ksi) vs 200 MPa (29 ksi).

Which condition does FabDigit quote by default, H112 or H32?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 5052-H112 or 5052-H32?

5052-H32, by a small margin. Both rate fair for machinability — 50/100 against 45/100 for 5052-H112.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5052-H112 and 5052-H32 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.