FabDigitFabDigit

Aluminum 5052-H111 vs 5052-H14

Aluminum · 5052 temper comparison

5052-H111 and 5052-H14 are two conditions of the same aluminum grade, 5052: H111 (slightly strain hardened) versus H14 (strain hardened, half hard). The chemistry is identical, so every difference below comes from the condition. 5052-H14 is the stronger of the two: yield strength 215 MPa (31.2 ksi) against 110 MPa (16 ksi) for 5052-H111, about 95% more; tensile strength follows at 260 MPa (37.7 ksi) vs 200 MPa (29 ksi). In exchange, 5052-H111 is the more ductile: elongation 20% versus 10% for 5052-H14, and 5052-H14 is harder (68 HB vs 50 HB). 5052-H111 runs hotter in service (180°C vs 120°C continuous). On the shop floor, 5052-H14 machines more easily (good vs fair).

5052-H111Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5052-H14Choose it when strength drives the design, or when the part is machined in volume.

5052-H111 vs 5052-H14: properties

5052-H1115052-H14

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

200 MPa29 ksi
260 MPa37.7 ksi

Yield Strength (0.2% offset)

110 MPa16 ksi
215 MPa31.2 ksi

Elongation at Break

20%
10%

Shear Strength

125 MPa18.1 ksi
145 MPa21 ksi

Fatigue Strength (Endurance Limit)

110 MPa16 ksi
125 MPa18.1 ksi

Hardness, Brinell

50 HB
68 HB

Hardness, Vickers

55 HV
68 HV

Same in both: Elastic (Young's) Modulus 70.3 GPa10.2 Msi · Shear Modulus 25.9 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.68 g/cm³0.1 lb/in³ · Melting Point (Solidus) 607°C1,125 °F · Liquidus Temperature 649°C1,200 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

144 W/m·K83.2 BTU/hr·ft·°F
138 W/m·K79.7 BTU/hr·ft·°F

Latent Heat of Fusion

393 J/g169 BTU/lb
385 J/g166 BTU/lb

Max Service Temperature (continuous)

180°C356 °F
120°C248 °F

Same in both: Specific Heat Capacity 880 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.8 µm/m·K13.2 µin/in·°F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 35 % IACS · Electrical Resistivity 4.93×10⁻⁸ Ω·m1.94 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

74 / 100
77 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.85 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
35%

Weldability

92 / 100
85 / 100

Formability (cold)

90 / 100
65 / 100

Polishability

70 / 100
65 / 100

Same in both: Brazeability / Solderability 20 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Carbon (primary production)

12 kg CO₂/kg
11.5 kg CO₂/kg

Same in both: Embodied Energy (primary production) 155 MJ/kg66,638 BTU/lb · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5052

5052-H111 vs 5052-H14 — frequently asked

Is 5052-H14 stronger than 5052-H111?

Yes. 5052-H14 has a typical yield strength of 215 MPa (31.2 ksi) against 110 MPa (16 ksi) for 5052-H111 — about 95% more. Tensile strength is 260 MPa (37.7 ksi) vs 200 MPa (29 ksi).

Which condition does FabDigit quote by default, H111 or H14?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 5052-H111 or 5052-H14?

5052-H14. Its machinability rates good (55/100) against fair (40/100) for 5052-H111; for welding the order is 5052-H111 first (excellent, 92/100) then 5052-H14 (excellent, 85/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5052-H111 and 5052-H14 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.