FabDigitFabDigit

Aluminum 5049-H111 vs 5049-H14

Aluminum · 5049 temper comparison

5049-H111 and 5049-H14 are two conditions of the same aluminum grade, 5049: H111 (slightly strain hardened) versus H14 (strain hardened, half hard). The chemistry is identical, so every difference below comes from the condition. 5049-H14 is the stronger of the two: yield strength 210 MPa (30.5 ksi) against 105 MPa (15.2 ksi) for 5049-H111, about 100% more; tensile strength follows at 265 MPa (38.4 ksi) vs 215 MPa (31.2 ksi). In exchange, 5049-H111 is the more ductile: elongation 21% versus 7% for 5049-H14, and 5049-H14 is harder (72 HB vs 50 HB). 5049-H111 runs hotter in service (150°C vs 120°C continuous). On the shop floor, 5049-H14 machines more easily (50 vs 37 out of 100).

5049-H111Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5049-H14Choose it when strength drives the design, or when the part is machined in volume.

5049-H111 vs 5049-H14: properties

5049-H1115049-H14

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

215 MPa31.2 ksi
265 MPa38.4 ksi

Yield Strength (0.2% offset)

105 MPa15.2 ksi
210 MPa30.5 ksi

Elongation at Break

21%
7%

Shear Strength

138 MPa20 ksi
160 MPa23.2 ksi

Fatigue Strength (Endurance Limit)

100 MPa14.5 ksi
118 MPa17.1 ksi

Hardness, Brinell

50 HB
72 HB

Hardness, Vickers

53 HV
77 HV

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.4 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.69 g/cm³0.1 lb/in³ · Melting Point (Solidus) 610°C1,130 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

139 W/m·K80.3 BTU/hr·ft·°F
137 W/m·K79.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
120°C248 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.7 µm/m·K13.2 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

36 % IACS
35 % IACS

Electrical Resistivity

4.79×10⁻⁸ Ω·m1.89 µΩ·in
4.93×10⁻⁸ Ω·m1.94 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

78 / 100
76 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.86 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

37 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

24%
34%

Weldability

90 / 100
85 / 100

Formability (cold)

86 / 100
55 / 100

Same in both: Castability 30 / 100 · Brazeability / Solderability 25 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5049

5049-H111 vs 5049-H14 — frequently asked

Is 5049-H14 stronger than 5049-H111?

Yes. 5049-H14 has a typical yield strength of 210 MPa (30.5 ksi) against 105 MPa (15.2 ksi) for 5049-H111 — about 100% more. Tensile strength is 265 MPa (38.4 ksi) vs 215 MPa (31.2 ksi).

Which condition does FabDigit quote by default, H111 or H14?

H22 is the default 5049 condition in the FabDigit quote flow (neither H111 nor H14). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 5049-H111 or 5049-H14?

5049-H14, by a small margin. Both rate fair for machinability — 50/100 against 37/100 for 5049-H111; for welding the order is 5049-H111 first (excellent, 90/100) then 5049-H14 (excellent, 85/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5049-H111 and 5049-H14 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.