FabDigitFabDigit

Aluminum 5021-H14 vs 5021-H32

Aluminum · 5021 temper comparison

5021-H14 and 5021-H32 are two conditions of the same aluminum grade, 5021: H14 (strain hardened, half hard) versus H32 (strain hardened and stabilized, quarter hard). The chemistry is identical, so every difference below comes from the condition. 5021-H14 is the stronger of the two: yield strength 210 MPa (30.5 ksi) against 185 MPa (26.8 ksi) for 5021-H32, about 14% more; tensile strength follows at 250 MPa (36.3 ksi) vs 230 MPa (33.4 ksi). In exchange, 5021-H32 is the more ductile: elongation 13% versus 9% for 5021-H14, and 5021-H14 is harder (70 HB vs 62 HB). 5021-H32 runs hotter in service (130°C vs 100°C continuous).

5021-H14Choose it when strength drives the design.

5021-H32Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5021-H14 vs 5021-H32: properties

5021-H145021-H32

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

250 MPa36.3 ksi
230 MPa33.4 ksi

Yield Strength (0.2% offset)

210 MPa30.5 ksi
185 MPa26.8 ksi

Elongation at Break

9%
13%

Shear Strength

145 MPa21 ksi
138 MPa20 ksi

Fatigue Strength (Endurance Limit)

125 MPa18.1 ksi
118 MPa17.1 ksi

Hardness, Brinell

70 HB
62 HB

Hardness, Vickers

75 HV
66 HV

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.68 g/cm³0.1 lb/in³ · Melting Point (Solidus) 607°C1,125 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

100°C212 °F
130°C266 °F

Same in both: Thermal Conductivity 138 W/m·K79.7 BTU/hr·ft·°F · Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.8 µm/m·K13.2 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 35 % IACS · Electrical Resistivity 4.9×10⁻⁸ Ω·m1.93 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

77 / 100
80 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.85 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

28%
26%

Formability (cold)

52 / 100
64 / 100

Same in both: Weldability 78 / 100 · Castability 25 / 100 · Brazeability / Solderability 25 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5021

5021-H14 vs 5021-H32 — frequently asked

Is 5021-H14 stronger than 5021-H32?

Yes. 5021-H14 has a typical yield strength of 210 MPa (30.5 ksi) against 185 MPa (26.8 ksi) for 5021-H32 — about 14% more. Tensile strength is 250 MPa (36.3 ksi) vs 230 MPa (33.4 ksi).

Which condition does FabDigit quote by default, H14 or H32?

H18 is the default 5021 condition in the FabDigit quote flow (neither H14 nor H32). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 5021-H14 over 5021-H32?

Pick 5021-H14 when strength drives the design. Pick 5021-H32 when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5021-H14 and 5021-H32 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.