FabDigitFabDigit

Aluminum 4047-F vs 4047-O

Aluminum · 4047 temper comparison

4047-F and 4047-O are two conditions of the same aluminum grade, 4047: F (as fabricated) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 4047-F is the stronger of the two: yield strength 70 MPa (10.2 ksi) against 55 MPa (7.98 ksi) for 4047-O, about 27% more; tensile strength follows at 170 MPa (24.7 ksi) vs 130 MPa (18.9 ksi). In exchange, 4047-O is the more ductile: elongation 22% versus 18% for 4047-F, and 4047-F is harder (52 HB vs 42 HB).

4047-FChoose it when strength drives the design.

4047-OChoose it when the part is bent, formed or impact-loaded.

4047-F vs 4047-O: properties

4047-F4047-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

170 MPa24.7 ksi
130 MPa18.9 ksi

Yield Strength (0.2% offset)

70 MPa10.2 ksi
55 MPa8 ksi

Elongation at Break

18%
22%

Shear Strength

105 MPa15.2 ksi
85 MPa12.3 ksi

Fatigue Strength (Endurance Limit)

60 MPa8.7 ksi
50 MPa7.3 ksi

Hardness, Brinell

52 HB
42 HB

Hardness, Vickers

58 HV
47 HV

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 72 GPa10.4 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.66 g/cm³0.1 lb/in³ · Melting Point (Solidus) 577°C1,071 °F · Liquidus Temperature 582°C1,080 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

155 W/m·K89.6 BTU/hr·ft·°F
160 W/m·K92.4 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20 µm/m·K11.1 µin/in·°F · Latent Heat of Fusion 505 J/g217 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

39 % IACS
40 % IACS

Electrical Resistivity

4.4×10⁻⁸ Ω·m1.73 µΩ·in
4.3×10⁻⁸ Ω·m1.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

58 / 100
60 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
25%

Weldability

92 / 100
94 / 100

Formability (cold)

35 / 100
45 / 100

Same in both: Castability 95 / 100 · Brazeability / Solderability 96 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale4047

4047-F vs 4047-O — frequently asked

Is 4047-F stronger than 4047-O?

Yes. 4047-F has a typical yield strength of 70 MPa (10.2 ksi) against 55 MPa (7.98 ksi) for 4047-O — about 27% more. Tensile strength is 170 MPa (24.7 ksi) vs 130 MPa (18.9 ksi).

Which condition does FabDigit quote by default, F or O?

F is the default 4047 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 4047-F or 4047-O?

4047-F, by a small margin. Both rate fair for machinability — 40/100 against 35/100 for 4047-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4047-F and 4047-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.