FabDigitFabDigit

Aluminum 4007-H22 vs 4007-H28

Aluminum · 4007 temper comparison

4007-H22 and 4007-H28 are two conditions of the same aluminum grade, 4007: H22 (strain hardened and partially annealed, quarter hard) versus H28 (strain hardened and partially annealed, full hard). The chemistry is identical, so every difference below comes from the condition. 4007-H28 is the stronger of the two: yield strength 220 MPa (31.9 ksi) against 135 MPa (19.6 ksi) for 4007-H22, about 63% more; tensile strength follows at 245 MPa (35.5 ksi) vs 180 MPa (26.1 ksi). In exchange, 4007-H22 is the more ductile: elongation 11% versus 3% for 4007-H28, and 4007-H28 is harder (68 HB vs 50 HB). 4007-H22 runs hotter in service (130°C vs 110°C continuous). On the shop floor, 4007-H28 machines more easily (good vs fair).

4007-H22Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

4007-H28Choose it when strength drives the design, or when the part is machined in volume.

4007-H22 vs 4007-H28: properties

4007-H224007-H28

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

180 MPa26.1 ksi
245 MPa35.5 ksi

Yield Strength (0.2% offset)

135 MPa19.6 ksi
220 MPa31.9 ksi

Elongation at Break

11%
3%

Compressive Strength

135 MPa19.6 ksi
220 MPa31.9 ksi

Shear Strength

108 MPa15.7 ksi
138 MPa20 ksi

Fatigue Strength (Endurance Limit)

60 MPa8.7 ksi
75 MPa10.9 ksi

Hardness, Brinell

50 HB
68 HB

Hardness, Vickers

53 HV
72 HV

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.4 GPa3.8 Msi · Bulk Modulus 72 GPa10.4 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.73 g/cm³0.1 lb/in³ · Melting Point (Solidus) 625°C1,157 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

163 W/m·K94.2 BTU/hr·ft·°F
160 W/m·K92.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

130°C266 °F
110°C230 °F

Same in both: Specific Heat Capacity 895 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22 µm/m·K12.2 µin/in·°F · Latent Heat of Fusion 393 J/g169 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

40 % IACS
39 % IACS

Electrical Resistivity

4.32×10⁻⁸ Ω·m1.7 µΩ·in
4.45×10⁻⁸ Ω·m1.75 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

57 / 100
55 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

54 / 100
64 / 100

Machinability Rating (AISI 1212 = 100 %)

130%
145%

Weldability

60 / 100
55 / 100

Formability (cold)

72 / 100
35 / 100

Same in both: Castability 70 / 100 · Brazeability / Solderability 80 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale4007

4007-H22 vs 4007-H28 — frequently asked

Is 4007-H28 stronger than 4007-H22?

Yes. 4007-H28 has a typical yield strength of 220 MPa (31.9 ksi) against 135 MPa (19.6 ksi) for 4007-H22 — about 63% more. Tensile strength is 245 MPa (35.5 ksi) vs 180 MPa (26.1 ksi).

Which condition does FabDigit quote by default, H22 or H28?

O is the default 4007 condition in the FabDigit quote flow (neither H22 nor H28). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 4007-H22 or 4007-H28?

4007-H28. Its machinability rates good (64/100) against fair (54/100) for 4007-H22; for welding the order is 4007-H22 first (good, 60/100) then 4007-H28 (good, 55/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4007-H22 and 4007-H28 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.