FabDigitFabDigit

Aluminum 4007-H111 vs 4007-H26

Aluminum · 4007 temper comparison

4007-H111 and 4007-H26 are two conditions of the same aluminum grade, 4007: H111 (slightly strain hardened) versus H26 (strain hardened and partially annealed, three-quarter hard). The chemistry is identical, so every difference below comes from the condition. 4007-H26 is the stronger of the two: yield strength 185 MPa (26.8 ksi) against 85 MPa (12.3 ksi) for 4007-H111, about 118% more; tensile strength follows at 220 MPa (31.9 ksi) vs 160 MPa (23.2 ksi). In exchange, 4007-H111 is the more ductile: elongation 22% versus 5% for 4007-H26, and 4007-H26 is harder (62 HB vs 46 HB). 4007-H111 runs hotter in service (150°C vs 110°C continuous). On the shop floor, 4007-H26 machines more easily (good vs fair).

4007-H111Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

4007-H26Choose it when strength drives the design, or when the part is machined in volume.

4007-H111 vs 4007-H26: properties

4007-H1114007-H26

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

160 MPa23.2 ksi
220 MPa31.9 ksi

Yield Strength (0.2% offset)

85 MPa12.3 ksi
185 MPa26.8 ksi

Elongation at Break

22%
5%

Compressive Strength

65 MPa9.4 ksi
185 MPa26.8 ksi

Shear Strength

100 MPa14.5 ksi
128 MPa18.6 ksi

Fatigue Strength (Endurance Limit)

58 MPa8.4 ksi
70 MPa10.2 ksi

Hardness, Brinell

46 HB
62 HB

Hardness, Vickers

50 HV
66 HV

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.4 GPa3.8 Msi · Bulk Modulus 72 GPa10.4 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.73 g/cm³0.1 lb/in³ · Melting Point (Solidus) 625°C1,157 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

163 W/m·K94.2 BTU/hr·ft·°F
161 W/m·K93 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
110°C230 °F

Same in both: Specific Heat Capacity 895 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22 µm/m·K12.2 µin/in·°F · Latent Heat of Fusion 393 J/g169 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

40 % IACS
39 % IACS

Electrical Resistivity

4.3×10⁻⁸ Ω·m1.69 µΩ·in
4.42×10⁻⁸ Ω·m1.74 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

58 / 100
56 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

47 / 100
61 / 100

Machinability Rating (AISI 1212 = 100 %)

120%
140%

Weldability

62 / 100
56 / 100

Formability (cold)

84 / 100
50 / 100

Same in both: Castability 70 / 100 · Brazeability / Solderability 80 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale4007

4007-H111 vs 4007-H26 — frequently asked

Is 4007-H26 stronger than 4007-H111?

Yes. 4007-H26 has a typical yield strength of 185 MPa (26.8 ksi) against 85 MPa (12.3 ksi) for 4007-H111 — about 118% more. Tensile strength is 220 MPa (31.9 ksi) vs 160 MPa (23.2 ksi).

Which condition does FabDigit quote by default, H111 or H26?

O is the default 4007 condition in the FabDigit quote flow (neither H111 nor H26). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 4007-H111 or 4007-H26?

4007-H26. Its machinability rates good (61/100) against fair (47/100) for 4007-H111; for welding the order is 4007-H111 first (good, 62/100) then 4007-H26 (good, 56/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 4007-H111 and 4007-H26 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.