FabDigitFabDigit

Aluminum 3A21-H112 vs 3A21-H14

Aluminum · 3A21 temper comparison

3A21-H112 and 3A21-H14 are two conditions of the same aluminum grade, 3A21: H112 (strain hardened from hot working only) versus H14 (strain hardened, half hard). The chemistry is identical, so every difference below comes from the condition. 3A21-H14 is the stronger of the two: yield strength 145 MPa (21 ksi) against 50 MPa (7.25 ksi) for 3A21-H112, about 190% more; tensile strength follows at 150 MPa (21.8 ksi) vs 115 MPa (16.7 ksi). In exchange, 3A21-H112 is the more ductile: elongation 22% versus 8% for 3A21-H14, and 3A21-H14 is harder (40 HB vs 30 HB). 3A21-H112 runs hotter in service (200°C vs 150°C continuous) and 3A21-H112 conducts heat better (190 W/m·K vs 159 W/m·K).

3A21-H112Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

3A21-H14Choose it when strength drives the design.

3A21-H112 vs 3A21-H14: properties

3A21-H1123A21-H14

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

115 MPa16.7 ksi
150 MPa21.8 ksi

Yield Strength (0.2% offset)

50 MPa7.3 ksi
145 MPa21 ksi

Elongation at Break

22%
8%

Shear Strength

76 MPa11 ksi
97 MPa14.1 ksi

Fatigue Strength (Endurance Limit)

48 MPa7 ksi
62 MPa9 ksi

Hardness, Brinell

30 HB
40 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 25 GPa3.6 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.73 g/cm³0.1 lb/in³ · Melting Point (Solidus) 643°C1,189 °F · Liquidus Temperature 654°C1,209 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

190 W/m·K110 BTU/hr·ft·°F
159 W/m·K91.9 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
150°C302 °F

Same in both: Specific Heat Capacity 893 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.2 µm/m·K12.9 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -250°C-418 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

49 % IACS
41 % IACS

Electrical Resistivity

3.52×10⁻⁸ Ω·m1.39 µΩ·in
4.2×10⁻⁸ Ω·m1.65 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

75 / 100
72 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

22%
30%

Weldability

95 / 100
92 / 100

Formability (cold)

88 / 100
70 / 100

Same in both: Brazeability / Solderability 90 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 13 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale3A21

3A21-H112 vs 3A21-H14 — frequently asked

Is 3A21-H14 stronger than 3A21-H112?

Yes. 3A21-H14 has a typical yield strength of 145 MPa (21 ksi) against 50 MPa (7.25 ksi) for 3A21-H112 — about 190% more. Tensile strength is 150 MPa (21.8 ksi) vs 115 MPa (16.7 ksi).

Which condition does FabDigit quote by default, H112 or H14?

H14 is the default 3A21 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 3A21-H112 or 3A21-H14?

3A21-H14. Its machinability rates fair (40/100) against poor (32/100) for 3A21-H112.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 3A21-H112 and 3A21-H14 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.