FabDigitFabDigit

Aluminum 364.0-F vs 364.0-T5

Aluminum · 364.0 temper comparison

364.0-F and 364.0-T5 are two conditions of the same aluminum grade, 364.0: F (as fabricated) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. 364.0-T5 is the stronger of the two: yield strength 200 MPa (29 ksi) against 159 MPa (23.1 ksi) for 364.0-F, about 26% more. In exchange, 364.0-F is the more ductile: elongation 7.5% versus 5% for 364.0-T5, and 364.0-T5 is harder (85 HB vs 75 HB). 364.0-T5 conducts electricity better (30 % IACS vs 27 % IACS).

364.0-FChoose it when the part is bent, formed or impact-loaded.

364.0-T5Choose it when strength drives the design.

364.0-F vs 364.0-T5: properties

364.0-F364.0-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

296 MPa42.9 ksi
305 MPa44.2 ksi

Yield Strength (0.2% offset)

159 MPa23.1 ksi
200 MPa29 ksi

Elongation at Break

7.5%
5%

Compressive Strength

165 MPa23.9 ksi
205 MPa29.7 ksi

Shear Strength

185 MPa26.8 ksi
190 MPa27.6 ksi

Fatigue Strength (Endurance Limit)

145 MPa21 ksi
150 MPa21.8 ksi

Fracture Toughness (K_IC)

17 MPa·√m15.5 ksi·√in
16 MPa·√m14.6 ksi·√in

Charpy V-Notch Impact (RT)

4 J3 ft·lbf
3 J2.2 ft·lbf

Hardness, Brinell

75 HB
85 HB

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.63 g/cm³0.1 lb/in³ · Melting Point (Solidus) 557°C1,035 °F · Liquidus Temperature 596°C1,105 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

105 W/m·K60.7 BTU/hr·ft·°F
113 W/m·K65.3 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21 µm/m·K11.7 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

27 % IACS
30 % IACS

Electrical Resistivity

6.4×10⁻⁸ Ω·m2.52 µΩ·in
5.75×10⁻⁸ Ω·m2.26 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

58 / 100
56 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
62 / 100

Same in both: Weldability 30 / 100 · Castability 90 / 100 · Brazeability / Solderability 20 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale364.0

364.0-F vs 364.0-T5 — frequently asked

Is 364.0-T5 stronger than 364.0-F?

Yes. 364.0-T5 has a typical yield strength of 200 MPa (29 ksi) against 159 MPa (23.1 ksi) for 364.0-F — about 26% more. Tensile strength is 305 MPa (44.2 ksi) vs 296 MPa (42.9 ksi).

Which condition does FabDigit quote by default, F or T5?

F is the default 364.0 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 364.0-F over 364.0-T5?

Pick 364.0-F when the part is bent, formed or impact-loaded. Pick 364.0-T5 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 364.0-F and 364.0-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.