FabDigitFabDigit

Aluminum 359.0-T6 vs 359.0-T62

Aluminum · 359.0 temper comparison

359.0-T6 and 359.0-T62 are two conditions of the same aluminum grade, 359.0: T6 (solution heat treated and artificially aged) versus T62 (T6, heat treated by the user). The chemistry is identical, so every difference below comes from the condition. 359.0-T62 is the stronger of the two: yield strength 285 MPa (41.3 ksi) against 250 MPa (36.3 ksi) for 359.0-T6, about 14% more; tensile strength follows at 340 MPa (49.3 ksi) vs 320 MPa (46.4 ksi). In exchange, 359.0-T6 is the more ductile: elongation 5% versus 4% for 359.0-T62, and 359.0-T62 is harder (90 HB vs 82 HB). 359.0-T62 runs hotter in service (175°C vs 150°C continuous).

359.0-T6Choose it when the part is bent, formed or impact-loaded.

359.0-T62Choose it when strength drives the design, or when the part sees heat.

359.0-T6 vs 359.0-T62: properties

359.0-T6359.0-T62

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

320 MPa46.4 ksi
340 MPa49.3 ksi

Yield Strength (0.2% offset)

250 MPa36.3 ksi
285 MPa41.3 ksi

Elongation at Break

5%
4%

Shear Strength

218 MPa31.6 ksi
230 MPa33.4 ksi

Fatigue Strength (Endurance Limit)

95 MPa13.8 ksi
100 MPa14.5 ksi

Fracture Toughness (K_IC)

22 MPa·√m20 ksi·√in
20 MPa·√m18.2 ksi·√in

Hardness, Brinell

82 HB
90 HB

Same in both: Elastic (Young's) Modulus 72 GPa10.4 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 74 GPa10.7 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.67 g/cm³0.1 lb/in³ · Melting Point (Solidus) 566°C1,051 °F · Liquidus Temperature 596°C1,105 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

138 W/m·K79.7 BTU/hr·ft·°F
143 W/m·K82.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
175°C347 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.9 µm/m·K11.6 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

35 % IACS
36 % IACS

Electrical Resistivity

4.9×10⁻⁸ Ω·m1.93 µΩ·in
4.8×10⁻⁸ Ω·m1.89 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

60 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
58 / 100

Same in both: Weldability 60 / 100 · Castability 90 / 100 · Brazeability / Solderability 20 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale359.0

359.0-T6 vs 359.0-T62 — frequently asked

Is 359.0-T62 stronger than 359.0-T6?

Yes. 359.0-T62 has a typical yield strength of 285 MPa (41.3 ksi) against 250 MPa (36.3 ksi) for 359.0-T6 — about 14% more. Tensile strength is 340 MPa (49.3 ksi) vs 320 MPa (46.4 ksi).

Which condition does FabDigit quote by default, T6 or T62?

T61 is the default 359.0 condition in the FabDigit quote flow (neither T6 nor T62). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 359.0-T6 over 359.0-T62?

Pick 359.0-T6 when the part is bent, formed or impact-loaded. Pick 359.0-T62 when strength drives the design, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 359.0-T6 and 359.0-T62 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.