FabDigitFabDigit

Aluminum 339.0-F vs 339.0-T6

Aluminum · 339.0 temper comparison

339.0-F and 339.0-T6 are two conditions of the same aluminum grade, 339.0: F (as fabricated) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 339.0-T6 is the stronger of the two: yield strength 255 MPa (37 ksi) against 140 MPa (20.3 ksi) for 339.0-F, about 82% more; tensile strength follows at 295 MPa (42.8 ksi) vs 215 MPa (31.2 ksi). In exchange, 339.0-F is the more ductile: elongation 1.5% versus 1% for 339.0-T6, and 339.0-T6 is harder (115 HB vs 80 HB). 339.0-T6 runs hotter in service (200°C vs 175°C continuous).

339.0-FChoose it when the part is bent, formed or impact-loaded.

339.0-T6Choose it when strength drives the design, or when the part sees heat.

339.0-F vs 339.0-T6: properties

339.0-F339.0-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

215 MPa31.2 ksi
295 MPa42.8 ksi

Yield Strength (0.2% offset)

140 MPa20.3 ksi
255 MPa37 ksi

Elongation at Break

1.5%
1%

Shear Strength

160 MPa23.2 ksi
220 MPa31.9 ksi

Fatigue Strength (Endurance Limit)

85 MPa12.3 ksi
105 MPa15.2 ksi

Fracture Toughness (K_IC)

17 MPa·√m15.5 ksi·√in
14 MPa·√m12.7 ksi·√in

Charpy V-Notch Impact (RT)

3 J2.2 ft·lbf
2 J1.1 ft·lbf

Hardness, Brinell

80 HB
115 HB

Same in both: Elastic (Young's) Modulus 81 GPa11.7 Msi · Shear Modulus 30 GPa4.4 Msi · Bulk Modulus 77 GPa11.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.73 g/cm³0.1 lb/in³ · Melting Point (Solidus) 505°C941 °F · Liquidus Temperature 580°C1,076 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

122 W/m·K70.5 BTU/hr·ft·°F
115 W/m·K66.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

175°C347 °F
200°C392 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 19.4 µm/m·K10.8 µin/in·°F · Latent Heat of Fusion 490 J/g211 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

29 % IACS
27 % IACS

Electrical Resistivity

5.9×10⁻⁸ Ω·m2.32 µΩ·in
6.4×10⁻⁸ Ω·m2.52 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

33 / 100
31 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.75 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

58%
52%

Weldability

24 / 100
20 / 100

Formability (cold)

5 / 100
3 / 100

Same in both: Castability 80 / 100 · Brazeability / Solderability 18 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 150 MJ/kg64,488 BTU/lb · Embodied Carbon (primary production) 9 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale339.0

339.0-F vs 339.0-T6 — frequently asked

Is 339.0-T6 stronger than 339.0-F?

Yes. 339.0-T6 has a typical yield strength of 255 MPa (37 ksi) against 140 MPa (20.3 ksi) for 339.0-F — about 82% more. Tensile strength is 295 MPa (42.8 ksi) vs 215 MPa (31.2 ksi).

Which condition does FabDigit quote by default, F or T6?

T5 is the default 339.0 condition in the FabDigit quote flow (neither F nor T6). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 339.0-F over 339.0-T6?

Pick 339.0-F when the part is bent, formed or impact-loaded. Pick 339.0-T6 when strength drives the design, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 339.0-F and 339.0-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.