FabDigitFabDigit

Aluminum 336.0-F vs 336.0-T7

Aluminum · 336.0 temper comparison

336.0-F and 336.0-T7 are two conditions of the same aluminum grade, 336.0: F (as fabricated) versus T7 (solution heat treated and overaged (stabilized)). The chemistry is identical, so every difference below comes from the condition. 336.0-T7 is the stronger of the two: yield strength 195 MPa (28.3 ksi) against 140 MPa (20.3 ksi) for 336.0-F, about 39% more; tensile strength follows at 240 MPa (34.8 ksi) vs 200 MPa (29 ksi). In exchange, 336.0-F is the more ductile: elongation 1% versus 0.8% for 336.0-T7, and 336.0-T7 is harder (100 HB vs 85 HB). 336.0-T7 runs hotter in service (260°C vs 200°C continuous).

336.0-FChoose it when the part is bent, formed or impact-loaded.

336.0-T7Choose it when strength drives the design, or when the part sees heat.

336.0-F vs 336.0-T7: properties

336.0-F336.0-T7

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

89 GPa12.9 Msi
90 GPa13.1 Msi

Tensile Strength (Ultimate)

200 MPa29 ksi
240 MPa34.8 ksi

Yield Strength (0.2% offset)

140 MPa20.3 ksi
195 MPa28.3 ksi

Elongation at Break

1%
0.8%

Shear Strength

150 MPa21.8 ksi
180 MPa26.1 ksi

Fatigue Strength (Endurance Limit)

85 MPa12.3 ksi
95 MPa13.8 ksi

Charpy V-Notch Impact (RT)

3 J2.2 ft·lbf
3 J1.8 ft·lbf

Hardness, Brinell

85 HB
100 HB

Same in both: Shear Modulus 34 GPa4.9 Msi · Bulk Modulus 76 GPa11 Msi · Poisson's Ratio 0.33 · Fracture Toughness (K_IC) 15 MPa·√m13.7 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 2.72 g/cm³0.1 lb/in³ · Melting Point (Solidus) 538°C1,000 °F · Liquidus Temperature 566°C1,051 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

122 W/m·K70.5 BTU/hr·ft·°F
120 W/m·K69.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
260°C500 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 19 µm/m·K10.6 µin/in·°F · Latent Heat of Fusion 480 J/g206 BTU/lb · Min Service Temperature -195°C-319 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

31 % IACS
30 % IACS

Electrical Resistivity

5.6×10⁻⁸ Ω·m2.2 µΩ·in
5.75×10⁻⁸ Ω·m2.26 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

45 / 100
46 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.79 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

38 / 100
37 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
58%

Weldability

38 / 100
35 / 100

Formability (cold)

6 / 100
5 / 100

Same in both: Castability 78 / 100 · Brazeability / Solderability 15 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 150 MJ/kg64,488 BTU/lb · Embodied Carbon (primary production) 9.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 55%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale336.0

336.0-F vs 336.0-T7 — frequently asked

Is 336.0-T7 stronger than 336.0-F?

Yes. 336.0-T7 has a typical yield strength of 195 MPa (28.3 ksi) against 140 MPa (20.3 ksi) for 336.0-F — about 39% more. Tensile strength is 240 MPa (34.8 ksi) vs 200 MPa (29 ksi).

Which condition does FabDigit quote by default, F or T7?

T551 is the default 336.0 condition in the FabDigit quote flow (neither F nor T7). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 336.0-F over 336.0-T7?

Pick 336.0-F when the part is bent, formed or impact-loaded. Pick 336.0-T7 when strength drives the design, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 336.0-F and 336.0-T7 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.