FabDigitFabDigit

Aluminum 3303-H112 vs 3303-H14

Aluminum · 3303 temper comparison

3303-H112 and 3303-H14 are two conditions of the same aluminum grade, 3303: H112 (strain hardened from hot working only) versus H14 (strain hardened, half hard). The chemistry is identical, so every difference below comes from the condition. 3303-H14 is the stronger of the two: yield strength 145 MPa (21 ksi) against 55 MPa (7.98 ksi) for 3303-H112, about 164% more; tensile strength follows at 150 MPa (21.8 ksi) vs 115 MPa (16.7 ksi). In exchange, 3303-H112 is the more ductile: elongation 25% versus 9% for 3303-H14, and 3303-H14 is harder (40 HB vs 30 HB). 3303-H112 conducts heat better (190 W/m·K vs 159 W/m·K).

3303-H112Choose it when the part is bent, formed or impact-loaded.

3303-H14Choose it when strength drives the design.

3303-H112 vs 3303-H14: properties

3303-H1123303-H14

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

115 MPa16.7 ksi
150 MPa21.8 ksi

Yield Strength (0.2% offset)

55 MPa8 ksi
145 MPa21 ksi

Elongation at Break

25%
9%

Shear Strength

78 MPa11.3 ksi
97 MPa14.1 ksi

Fatigue Strength (Endurance Limit)

50 MPa7.3 ksi
62 MPa9 ksi

Hardness, Brinell

30 HB
40 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 25 GPa3.6 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.73 g/cm³0.1 lb/in³ · Melting Point (Solidus) 643°C1,189 °F · Liquidus Temperature 654°C1,209 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

190 W/m·K110 BTU/hr·ft·°F
159 W/m·K91.9 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 893 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.2 µm/m·K12.9 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

49 % IACS
41 % IACS

Electrical Resistivity

3.52×10⁻⁸ Ω·m1.39 µΩ·in
3.45×10⁻⁸ Ω·m1.36 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

68 / 100
70 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

27%
30%

Weldability

88 / 100
90 / 100

Formability (cold)

88 / 100
70 / 100

Same in both: Brazeability / Solderability 90 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale3303

3303-H112 vs 3303-H14 — frequently asked

Is 3303-H14 stronger than 3303-H112?

Yes. 3303-H14 has a typical yield strength of 145 MPa (21 ksi) against 55 MPa (7.98 ksi) for 3303-H112 — about 164% more. Tensile strength is 150 MPa (21.8 ksi) vs 115 MPa (16.7 ksi).

Which condition does FabDigit quote by default, H112 or H14?

O is the default 3303 condition in the FabDigit quote flow (neither H112 nor H14). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 3303-H112 or 3303-H14?

3303-H14. Its machinability rates fair (38/100) against poor (32/100) for 3303-H112.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 3303-H112 and 3303-H14 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.