FabDigitFabDigit

Aluminum 324.0-T5 vs 324.0-T62

Aluminum · 324.0 temper comparison

324.0-T5 and 324.0-T62 are two conditions of the same aluminum grade, 324.0: T5 (cooled from hot working and artificially aged) versus T62 (T6, heat treated by the user). The chemistry is identical, so every difference below comes from the condition. 324.0-T62 is the stronger of the two: yield strength 248 MPa (36 ksi) against 193 MPa (28 ksi) for 324.0-T5, about 28% more; tensile strength follows at 296 MPa (42.9 ksi) vs 248 MPa (36 ksi). 324.0-T62 is harder — 105 HB against 90 HB for 324.0-T5 — which matters for wear surfaces and threads.

324.0-T62Choose it when strength drives the design, or when surface hardness matters.

324.0-T5 vs 324.0-T62: properties

324.0-T5324.0-T62

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

248 MPa36 ksi
296 MPa42.9 ksi

Yield Strength (0.2% offset)

193 MPa28 ksi
248 MPa36 ksi

Shear Strength

179 MPa26 ksi
205 MPa29.7 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
96 MPa13.9 ksi

Charpy V-Notch Impact (RT)

4 J3 ft·lbf
3 J2.2 ft·lbf

Hardness, Brinell

90 HB
105 HB

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 72 GPa10.4 Msi · Poisson's Ratio 0.33 · Elongation at Break 3% · Fracture Toughness (K_IC) 18 MPa·√m16.4 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 2.72 g/cm³0.1 lb/in³ · Melting Point (Solidus) 549°C1,020 °F · Liquidus Temperature 613°C1,135 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

151 W/m·K87.2 BTU/hr·ft·°F
155 W/m·K89.6 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Max Service Temperature (continuous) 175°C347 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

36 % IACS
38 % IACS

Same in both: Electrical Resistivity 4.8×10⁻⁸ Ω·m1.89 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.8 V · Corrosion Resistance 45 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
60 / 100

Same in both: Weldability 45 / 100 · Formability (cold) 10 / 100 · Castability 85 / 100 · Brazeability / Solderability 25 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale324.0

324.0-T5 vs 324.0-T62 — frequently asked

Is 324.0-T62 stronger than 324.0-T5?

Yes. 324.0-T62 has a typical yield strength of 248 MPa (36 ksi) against 193 MPa (28 ksi) for 324.0-T5 — about 28% more. Tensile strength is 296 MPa (42.9 ksi) vs 248 MPa (36 ksi).

Which condition does FabDigit quote by default, T5 or T62?

T5 is the default 324.0 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 324.0-T5 or 324.0-T62?

324.0-T62, by a small margin. Both rate good for machinability — 60/100 against 55/100 for 324.0-T5.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 324.0-T5 and 324.0-T62 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.