FabDigitFabDigit

Aluminum 3103-H112 vs 3103-H12

Aluminum · 3103 temper comparison

3103-H112 and 3103-H12 are two conditions of the same aluminum grade, 3103: H112 (strain hardened from hot working only) versus H12 (strain hardened, quarter hard). The chemistry is identical, so every difference below comes from the condition. 3103-H12 is the stronger of the two: yield strength 105 MPa (15.2 ksi) against 50 MPa (7.25 ksi) for 3103-H112, about 110% more; tensile strength follows at 130 MPa (18.9 ksi) vs 110 MPa (16 ksi). In exchange, 3103-H112 is the more ductile: elongation 20% versus 9% for 3103-H12, and 3103-H12 is harder (37 HB vs 30 HB). 3103-H112 runs hotter in service (150°C vs 120°C continuous) and 3103-H112 conducts heat better (185 W/m·K vs 163 W/m·K).

3103-H112Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

3103-H12Choose it when strength drives the design.

3103-H112 vs 3103-H12: properties

3103-H1123103-H12

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

110 MPa16 ksi
130 MPa18.9 ksi

Yield Strength (0.2% offset)

50 MPa7.3 ksi
105 MPa15.2 ksi

Elongation at Break

20%
9%

Shear Strength

75 MPa10.9 ksi
88 MPa12.8 ksi

Fatigue Strength (Endurance Limit)

45 MPa6.5 ksi
55 MPa8 ksi

Hardness, Brinell

30 HB
37 HB

Hardness, Vickers

33 HV
42 HV

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.73 g/cm³0.1 lb/in³ · Melting Point (Solidus) 645°C1,193 °F · Liquidus Temperature 655°C1,211 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

185 W/m·K107 BTU/hr·ft·°F
163 W/m·K94.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
120°C248 °F

Same in both: Specific Heat Capacity 893 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.2 µm/m·K12.9 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

48 % IACS
43 % IACS

Electrical Resistivity

3.6×10⁻⁸ Ω·m1.42 µΩ·in
4×10⁻⁸ Ω·m1.57 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

72 / 100
70 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
32 / 100

Machinability Rating (AISI 1212 = 100 %)

22%
28%

Weldability

92 / 100
90 / 100

Formability (cold)

85 / 100
75 / 100

Same in both: Brazeability / Solderability 75 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale3103

3103-H112 vs 3103-H12 — frequently asked

Is 3103-H12 stronger than 3103-H112?

Yes. 3103-H12 has a typical yield strength of 105 MPa (15.2 ksi) against 50 MPa (7.25 ksi) for 3103-H112 — about 110% more. Tensile strength is 130 MPa (18.9 ksi) vs 110 MPa (16 ksi).

Which condition does FabDigit quote by default, H112 or H12?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 3103-H112 or 3103-H12?

3103-H12, by a small margin. Both rate poor for machinability — 32/100 against 25/100 for 3103-H112.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 3103-H112 and 3103-H12 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.