FabDigitFabDigit

Aluminum 3004-H14 vs 3004-O

Aluminum · 3004 temper comparison

3004-H14 and 3004-O are two conditions of the same aluminum grade, 3004: H14 (strain hardened, half hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 3004-H14 is the stronger of the two: yield strength 215 MPa (31.2 ksi) against 70 MPa (10.2 ksi) for 3004-O, about 3.1 times as much; tensile strength follows at 245 MPa (35.5 ksi) vs 180 MPa (26.1 ksi). In exchange, 3004-O is the more ductile: elongation 22% versus 7% for 3004-H14, and 3004-H14 is harder (66 HB vs 45 HB). 3004-O runs hotter in service (200°C vs 150°C continuous). On the shop floor, 3004-H14 machines more easily (52 vs 35 out of 100).

3004-H14Choose it when strength drives the design, or when the part is machined in volume.

3004-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

3004-H14 vs 3004-O: properties

3004-H143004-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

245 MPa35.5 ksi
180 MPa26.1 ksi

Yield Strength (0.2% offset)

215 MPa31.2 ksi
70 MPa10.2 ksi

Elongation at Break

7%
22%

Compressive Strength

220 MPa31.9 ksi
205 MPa29.7 ksi

Shear Strength

125 MPa18.1 ksi
110 MPa16 ksi

Fatigue Strength (Endurance Limit)

105 MPa15.2 ksi
95 MPa13.8 ksi

Hardness, Brinell

66 HB
45 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 72 GPa10.4 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.72 g/cm³0.1 lb/in³ · Melting Point (Solidus) 629°C1,164 °F · Liquidus Temperature 654°C1,209 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

162 W/m·K93.6 BTU/hr·ft·°F
163 W/m·K94.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Specific Heat Capacity 893 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.2 µm/m·K12.9 µin/in·°F · Latent Heat of Fusion 393 J/g169 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 42 % IACS · Electrical Resistivity 4.1×10⁻⁸ Ω·m1.61 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.84 V · Corrosion Resistance 68 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

52 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

90%
55%

Formability (cold)

60 / 100
95 / 100

Same in both: Weldability 88 / 100 · Brazeability / Solderability 45 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 55%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale3004

3004-H14 vs 3004-O — frequently asked

Is 3004-H14 stronger than 3004-O?

Yes. 3004-H14 has a typical yield strength of 215 MPa (31.2 ksi) against 70 MPa (10.2 ksi) for 3004-O — about 3.1 times as much. Tensile strength is 245 MPa (35.5 ksi) vs 180 MPa (26.1 ksi).

Which condition does FabDigit quote by default, H14 or O?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 3004-H14 or 3004-O?

3004-H14, by a small margin. Both rate fair for machinability — 52/100 against 35/100 for 3004-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 3004-H14 and 3004-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.