2A10-O and 2A10-T6 are two conditions of the same aluminum grade, 2A10: O (annealed) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 2A10-T6 is the stronger of the two: yield strength 340 MPa (49.3 ksi) against 80 MPa (11.6 ksi) for 2A10-O, about 4.3 times as much; tensile strength follows at 420 MPa (60.9 ksi) vs 185 MPa (26.8 ksi). In exchange, 2A10-O is the more ductile: elongation 24% versus 10% for 2A10-T6, and 2A10-T6 is harder (118 HB vs 45 HB). 2A10-O conducts heat better (185 W/m·K vs 145 W/m·K). On the shop floor, 2A10-T6 machines more easily (very good vs fair).

2A10-OChoose it when the part is bent, formed or impact-loaded.

2A10-T6Choose it when strength drives the design, or when the part is machined in volume.

2A10-O vs 2A10-T6: properties

2A10-O2A10-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

185 MPa26.8 ksi
420 MPa60.9 ksi

Yield Strength (0.2% offset)

80 MPa11.6 ksi
340 MPa49.3 ksi

Elongation at Break

24%
10%

Shear Strength

125 MPa18.1 ksi
270 MPa39.2 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
130 MPa18.9 ksi

Hardness, Brinell

45 HB
118 HB

Hardness, Rockwell B

62 HRB
70 HRB

Same in both: Elastic (Young's) Modulus 72 GPa10.4 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33 · Fracture Toughness (K_IC) 30 MPa·√m27.3 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 2.8 g/cm³0.1 lb/in³ · Melting Point (Solidus) 512°C954 °F · Liquidus Temperature 640°C1,184 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

185 W/m·K107 BTU/hr·ft·°F
145 W/m·K83.8 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 875 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.9 µm/m·K12.7 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

45 % IACS
35 % IACS

Electrical Resistivity

3.8×10⁻⁸ Ω·m1.5 µΩ·in
4.9×10⁻⁸ Ω·m1.93 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

38 / 100
36 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.69 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
75 / 100

Formability (cold)

80 / 100
25 / 100

Same in both: Weldability 18 / 100 · Brazeability / Solderability 15 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 10%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale2A10

2A10-O vs 2A10-T6 — frequently asked

Is 2A10-T6 stronger than 2A10-O?

Yes. 2A10-T6 has a typical yield strength of 340 MPa (49.3 ksi) against 80 MPa (11.6 ksi) for 2A10-O — about 4.3 times as much. Tensile strength is 420 MPa (60.9 ksi) vs 185 MPa (26.8 ksi).

Which condition does FabDigit quote by default, O or T6?

T4 is the default 2A10 condition in the FabDigit quote flow (neither O nor T6). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 2A10-O or 2A10-T6?

2A10-T6. Its machinability rates very good (75/100) against fair (45/100) for 2A10-O.