FabDigitFabDigit

Aluminum 249.0-F vs 249.0-T4

Aluminum · 249.0 temper comparison

249.0-F and 249.0-T4 are two conditions of the same aluminum grade, 249.0: F (as fabricated) versus T4 (solution heat treated and naturally aged). The chemistry is identical, so every difference below comes from the condition. 249.0-T4 is the stronger of the two: yield strength 200 MPa (29 ksi) against 110 MPa (16 ksi) for 249.0-F, about 82% more; tensile strength follows at 330 MPa (47.9 ksi) vs 195 MPa (28.3 ksi). 249.0-T4 is the more ductile: elongation 12% versus 2.5% for 249.0-F, and 249.0-T4 is harder (85 HB vs 65 HB). 249.0-F runs hotter in service (120°C vs 100°C continuous) and 249.0-F conducts heat better (140 W/m·K vs 110 W/m·K).

249.0-FChoose it when the part sees heat.

249.0-T4Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

249.0-F vs 249.0-T4: properties

249.0-F249.0-T4

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

195 MPa28.3 ksi
330 MPa47.9 ksi

Yield Strength (0.2% offset)

110 MPa16 ksi
200 MPa29 ksi

Elongation at Break

2.5%
12%

Compressive Strength

125 MPa18.1 ksi
350 MPa50.8 ksi

Shear Strength

130 MPa18.9 ksi
250 MPa36.3 ksi

Fatigue Strength (Endurance Limit)

60 MPa8.7 ksi
90 MPa13.1 ksi

Fracture Toughness (K_IC)

20 MPa·√m18.2 ksi·√in
33 MPa·√m30 ksi·√in

Hardness, Brinell

65 HB
85 HB

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.81 g/cm³0.1 lb/in³ · Melting Point (Solidus) 540°C1,004 °F · Liquidus Temperature 640°C1,184 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

140 W/m·K80.9 BTU/hr·ft·°F
110 W/m·K63.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
100°C212 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.8 µm/m·K12.7 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

38 % IACS
29 % IACS

Electrical Resistivity

4.5×10⁻⁸ Ω·m1.77 µΩ·in
5.2×10⁻⁸ Ω·m2.05 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

40 / 100
38 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.7 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
65 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
60%

Same in both: Weldability 25 / 100 · Castability 40 / 100 · Brazeability / Solderability 15 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 10%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale249.0

249.0-F vs 249.0-T4 — frequently asked

Is 249.0-T4 stronger than 249.0-F?

Yes. 249.0-T4 has a typical yield strength of 200 MPa (29 ksi) against 110 MPa (16 ksi) for 249.0-F — about 82% more. Tensile strength is 330 MPa (47.9 ksi) vs 195 MPa (28.3 ksi).

Which condition does FabDigit quote by default, F or T4?

T7 is the default 249.0 condition in the FabDigit quote flow (neither F nor T4). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 249.0-F or 249.0-T4?

249.0-T4, by a small margin. Both rate good for machinability — 65/100 against 60/100 for 249.0-F.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 249.0-F and 249.0-T4 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.