FabDigitFabDigit

Aluminum 2124-T351 vs 2124-T851

Aluminum · 2124 temper comparison

2124-T351 and 2124-T851 are two conditions of the same aluminum grade, 2124: T351 (T3, stress relieved by stretching) versus T851 (T8, stress relieved by stretching). The chemistry is identical, so every difference below comes from the condition. 2124-T851 is the stronger of the two: yield strength 440 MPa (63.8 ksi) against 325 MPa (47.1 ksi) for 2124-T351, about 35% more. In exchange, 2124-T351 is the more ductile: elongation 15% versus 8% for 2124-T851, and 2124-T851 is harder (128 HB vs 120 HB). 2124-T851 runs hotter in service (150°C vs 100°C continuous) and 2124-T851 conducts heat better (152 W/m·K vs 121 W/m·K).

2124-T351Choose it when the part is bent, formed or impact-loaded.

2124-T851Choose it when strength drives the design, or when the part sees heat.

2124-T351 vs 2124-T851: properties

2124-T3512124-T851

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

470 MPa68.2 ksi
490 MPa71.1 ksi

Yield Strength (0.2% offset)

325 MPa47.1 ksi
440 MPa63.8 ksi

Elongation at Break

15%
8%

Fatigue Strength (Endurance Limit)

140 MPa20.3 ksi
138 MPa20 ksi

Fracture Toughness (K_IC)

37 MPa·√m33.7 ksi·√in
34 MPa·√m30.9 ksi·√in

Hardness, Brinell

120 HB
128 HB

Same in both: Elastic (Young's) Modulus 73.1 GPa10.6 Msi · Shear Modulus 28 GPa4.1 Msi · Bulk Modulus 76 GPa11 Msi · Poisson's Ratio 0.33 · Compressive Strength 450 MPa65.3 ksi · Shear Strength 285 MPa41.3 ksi

Physical

Density and transition temperatures.

Same in both: Density 2.78 g/cm³0.1 lb/in³ · Melting Point (Solidus) 502°C936 °F · Liquidus Temperature 638°C1,180 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

121 W/m·K69.9 BTU/hr·ft·°F
152 W/m·K87.8 BTU/hr·ft·°F

Max Service Temperature (continuous)

100°C212 °F
150°C302 °F

Same in both: Specific Heat Capacity 875 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.9 µm/m·K12.7 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

30 % IACS
38 % IACS

Electrical Resistivity

5.75×10⁻⁸ Ω·m2.26 µΩ·in
4.5×10⁻⁸ Ω·m1.77 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

25 / 100
30 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.64 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

70 / 100
78 / 100

Formability (cold)

40 / 100
25 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 70% · Weldability 20 / 100 · Brazeability / Solderability 10 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 210 MJ/kg90,284 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 5%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale2124

2124-T351 vs 2124-T851 — frequently asked

Is 2124-T851 stronger than 2124-T351?

Yes. 2124-T851 has a typical yield strength of 440 MPa (63.8 ksi) against 325 MPa (47.1 ksi) for 2124-T351 — about 35% more. Tensile strength is 490 MPa (71.1 ksi) vs 470 MPa (68.2 ksi).

Which condition does FabDigit quote by default, T351 or T851?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 2124-T351 or 2124-T851?

2124-T851, by a small margin. Both rate very good for machinability — 78/100 against 70/100 for 2124-T351.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 2124-T351 and 2124-T851 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.