FabDigitFabDigit

Aluminum 2124-T3 vs 2124-T8511

Aluminum · 2124 temper comparison

2124-T3 and 2124-T8511 are two conditions of the same aluminum grade, 2124: T3 (solution heat treated, cold worked and naturally aged) versus T8511 (solution treated, stress relieved by stretching with minor…). The chemistry is identical, so every difference below comes from the condition. 2124-T8511 is the stronger of the two: yield strength 435 MPa (63.1 ksi) against 325 MPa (47.1 ksi) for 2124-T3, about 34% more. In exchange, 2124-T3 is the more ductile: elongation 15% versus 7% for 2124-T8511. 2124-T8511 runs hotter in service (150°C vs 120°C continuous) and 2124-T8511 conducts heat better (152 W/m·K vs 121 W/m·K).

2124-T3Choose it when the part is bent, formed or impact-loaded.

2124-T8511Choose it when strength drives the design, or when the part sees heat.

2124-T3 vs 2124-T8511: properties

2124-T32124-T8511

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

470 MPa68.2 ksi
480 MPa69.6 ksi

Yield Strength (0.2% offset)

325 MPa47.1 ksi
435 MPa63.1 ksi

Elongation at Break

15%
7%

Compressive Strength

335 MPa48.6 ksi
445 MPa64.5 ksi

Shear Strength

283 MPa41 ksi
280 MPa40.6 ksi

Fatigue Strength (Endurance Limit)

138 MPa20 ksi
135 MPa19.6 ksi

Fracture Toughness (K_IC)

38 MPa·√m34.6 ksi·√in
31 MPa·√m28.2 ksi·√in

Hardness, Brinell

120 HB
126 HB

Same in both: Elastic (Young's) Modulus 73.1 GPa10.6 Msi · Shear Modulus 28 GPa4.1 Msi · Bulk Modulus 76 GPa11 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.78 g/cm³0.1 lb/in³ · Melting Point (Solidus) 502°C936 °F · Liquidus Temperature 638°C1,180 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

121 W/m·K69.9 BTU/hr·ft·°F
152 W/m·K87.8 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
150°C302 °F

Same in both: Specific Heat Capacity 875 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.9 µm/m·K12.7 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

30 % IACS
38 % IACS

Electrical Resistivity

5.75×10⁻⁸ Ω·m2.26 µΩ·in
4.5×10⁻⁸ Ω·m1.77 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

28 / 100
30 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.64 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

72 / 100
78 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
70%

Formability (cold)

45 / 100
20 / 100

Same in both: Weldability 20 / 100 · Brazeability / Solderability 10 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 210 MJ/kg90,284 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 5%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale2124

2124-T3 vs 2124-T8511 — frequently asked

Is 2124-T8511 stronger than 2124-T3?

Yes. 2124-T8511 has a typical yield strength of 435 MPa (63.1 ksi) against 325 MPa (47.1 ksi) for 2124-T3 — about 34% more. Tensile strength is 480 MPa (69.6 ksi) vs 470 MPa (68.2 ksi).

Which condition does FabDigit quote by default, T3 or T8511?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 2124-T3 or 2124-T8511?

2124-T8511, by a small margin. Both rate very good for machinability — 78/100 against 72/100 for 2124-T3.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 2124-T3 and 2124-T8511 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.