FabDigitFabDigit

Aluminum 2099-O vs 2099 T8E67

Aluminum · 2099 temper comparison

2099-O and 2099 T8E67 are two conditions of the same aluminum grade, 2099: O (annealed) versus T8E67 (proprietary T8-type age for thick/heavy extrusions and forgings). The chemistry is identical, so every difference below comes from the condition. 2099 T8E67 is the stronger of the two: yield strength 495 MPa (71.8 ksi) against 145 MPa (21 ksi) for 2099-O, about 3.4 times as much; tensile strength follows at 545 MPa (79 ksi) vs 270 MPa (39.2 ksi). In exchange, 2099-O is the more ductile: elongation 18% versus 9% for 2099 T8E67, and 2099 T8E67 is harder (145 HB vs 75 HB). On the shop floor, 2099 T8E67 machines more easily (good vs fair) and 2099-O welds better (33 vs 22 out of 100).

2099-OChoose it when the part is bent, formed or impact-loaded, or when it will be welded.

2099 T8E67Choose it when strength drives the design, or when the part is machined in volume.

2099-O vs 2099 T8E67: properties

2099-O2099 T8E67

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

270 MPa39.2 ksi
545 MPa79 ksi

Yield Strength (0.2% offset)

145 MPa21 ksi
495 MPa71.8 ksi

Elongation at Break

18%
9%

Compressive Strength

150 MPa21.8 ksi
510 MPa74 ksi

Shear Strength

170 MPa24.7 ksi
320 MPa46.4 ksi

Fatigue Strength (Endurance Limit)

95 MPa13.8 ksi
170 MPa24.7 ksi

Fracture Toughness (K_IC)

45 MPa·√m41 ksi·√in
38 MPa·√m34.6 ksi·√in

Hardness, Brinell

75 HB
145 HB

Same in both: Elastic (Young's) Modulus 78 GPa11.3 Msi · Shear Modulus 29.5 GPa4.3 Msi · Bulk Modulus 76 GPa11 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.63 g/cm³0.1 lb/in³ · Melting Point (Solidus) 560°C1,040 °F · Liquidus Temperature 645°C1,193 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

126 W/m·K72.8 BTU/hr·ft·°F
114 W/m·K65.9 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.9 µm/m·K12.2 µin/in·°F · Latent Heat of Fusion 385 J/g166 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -253°C-423 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

34 % IACS
31 % IACS

Electrical Resistivity

5.1×10⁻⁸ Ω·m2.01 µΩ·in
5.6×10⁻⁸ Ω·m2.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

50 / 100
45 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.8 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
65 / 100

Weldability

33 / 100
22 / 100

Formability (cold)

70 / 100
25 / 100

Same in both: Brazeability / Solderability 15 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 215 MJ/kg92,433 BTU/lb · Embodied Carbon (primary production) 13.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 5%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale2099

2099-O vs 2099 T8E67 — frequently asked

Is 2099 T8E67 stronger than 2099-O?

Yes. 2099 T8E67 has a typical yield strength of 495 MPa (71.8 ksi) against 145 MPa (21 ksi) for 2099-O — about 3.4 times as much. Tensile strength is 545 MPa (79 ksi) vs 270 MPa (39.2 ksi).

Which condition does FabDigit quote by default, O or T8E67?

T83 is the default 2099 condition in the FabDigit quote flow (neither O nor T8E67). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 2099-O or 2099 T8E67?

2099 T8E67. Its machinability rates good (65/100) against fair (45/100) for 2099-O; for welding the order is 2099-O first (poor, 33/100) then 2099 T8E67 (poor, 22/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 2099-O and 2099 T8E67 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.