FabDigitFabDigit

Aluminum 2098-O vs 2098-T3

Aluminum · 2098 temper comparison

2098-O and 2098-T3 are two conditions of the same aluminum grade, 2098: O (annealed) versus T3 (solution heat treated, cold worked and naturally aged). The chemistry is identical, so every difference below comes from the condition. 2098-T3 is the stronger of the two: yield strength 300 MPa (43.5 ksi) against 140 MPa (20.3 ksi) for 2098-O, about 114% more; tensile strength follows at 410 MPa (59.5 ksi) vs 265 MPa (38.4 ksi). In exchange, 2098-O is the more ductile: elongation 17% versus 14% for 2098-T3, and 2098-T3 is harder (115 HB vs 70 HB). 2098-O runs hotter in service (150°C vs 120°C continuous) and 2098-O conducts heat better (120 W/m·K vs 90 W/m·K). On the shop floor, 2098-T3 machines more easily (50 vs 40 out of 100) and 2098-O welds better (fair vs poor).

2098-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

2098-T3Choose it when strength drives the design, or when the part is machined in volume.

2098-O vs 2098-T3: properties

2098-O2098-T3

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

265 MPa38.4 ksi
410 MPa59.5 ksi

Yield Strength (0.2% offset)

140 MPa20.3 ksi
300 MPa43.5 ksi

Elongation at Break

17%
14%

Compressive Strength

145 MPa21 ksi
310 MPa45 ksi

Shear Strength

165 MPa23.9 ksi
250 MPa36.3 ksi

Fatigue Strength (Endurance Limit)

95 MPa13.8 ksi
140 MPa20.3 ksi

Fracture Toughness (K_IC)

55 MPa·√m50.1 ksi·√in
45 MPa·√m41 ksi·√in

Hardness, Brinell

70 HB
115 HB

Hardness, Vickers

74 HV
121 HV

Same in both: Elastic (Young's) Modulus 76 GPa11 Msi · Shear Modulus 29 GPa4.2 Msi · Bulk Modulus 74 GPa10.7 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 545°C1,013 °F · Liquidus Temperature 640°C1,184 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

120 W/m·K69.3 BTU/hr·ft·°F
90 W/m·K52 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
120°C248 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.3 µm/m·K12.4 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

38 % IACS
28 % IACS

Electrical Resistivity

4.5×10⁻⁸ Ω·m1.77 µΩ·in
6.2×10⁻⁸ Ω·m2.44 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

50 / 100
35 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.7 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

42%
52%

Weldability

35 / 100
25 / 100

Formability (cold)

65 / 100
45 / 100

Same in both: Brazeability / Solderability 10 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 215 MJ/kg92,433 BTU/lb · Embodied Carbon (primary production) 13.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 5%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale2098

2098-O vs 2098-T3 — frequently asked

Is 2098-T3 stronger than 2098-O?

Yes. 2098-T3 has a typical yield strength of 300 MPa (43.5 ksi) against 140 MPa (20.3 ksi) for 2098-O — about 114% more. Tensile strength is 410 MPa (59.5 ksi) vs 265 MPa (38.4 ksi).

Which condition does FabDigit quote by default, O or T3?

T851 is the default 2098 condition in the FabDigit quote flow (neither O nor T3). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 2098-O or 2098-T3?

2098-T3, by a small margin. Both rate fair for machinability — 50/100 against 40/100 for 2098-O; for welding the order is 2098-O first (fair, 35/100) then 2098-T3 (poor, 25/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 2098-O and 2098-T3 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.