FabDigitFabDigit

Aluminum 2018-F vs 2018-O

Aluminum · 2018 temper comparison

2018-F and 2018-O are two conditions of the same aluminum grade, 2018: F (as fabricated) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 2018-F is the stronger of the two: yield strength 140 MPa (20.3 ksi) against 70 MPa (10.2 ksi) for 2018-O, about 100% more; tensile strength follows at 250 MPa (36.3 ksi) vs 140 MPa (20.3 ksi). In exchange, 2018-O is the more ductile: elongation 20% versus 15% for 2018-F, and 2018-F is harder (70 HB vs 45 HB). 2018-O runs hotter in service (200°C vs 150°C continuous). On the shop floor, 2018-F machines more easily (good vs fair).

2018-FChoose it when strength drives the design, or when the part is machined in volume.

2018-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

2018-F vs 2018-O: properties

2018-F2018-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

250 MPa36.3 ksi
140 MPa20.3 ksi

Yield Strength (0.2% offset)

140 MPa20.3 ksi
70 MPa10.2 ksi

Elongation at Break

15%
20%

Compressive Strength

145 MPa21 ksi
320 MPa46.4 ksi

Shear Strength

160 MPa23.2 ksi
95 MPa13.8 ksi

Fatigue Strength (Endurance Limit)

85 MPa12.3 ksi
115 MPa16.7 ksi

Fracture Toughness (K_IC)

30 MPa·√m27.3 ksi·√in
22 MPa·√m20 ksi·√in

Hardness, Brinell

70 HB
45 HB

Hardness, Vickers

75 HV
128 HV

Same in both: Elastic (Young's) Modulus 74 GPa10.7 Msi · Shear Modulus 28 GPa4.1 Msi · Bulk Modulus 76 GPa11 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.8 g/cm³0.1 lb/in³ · Melting Point (Solidus) 507°C945 °F · Liquidus Temperature 638°C1,180 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Thermal Conductivity 172 W/m·K99.4 BTU/hr·ft·°F · Specific Heat Capacity 875 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.3 µm/m·K12.4 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

44 % IACS
46 % IACS

Electrical Resistivity

3.92×10⁻⁸ Ω·m1.54 µΩ·in
4.31×10⁻⁸ Ω·m1.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

35 / 100
38 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.7 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
45 / 100

Weldability

25 / 100
22 / 100

Formability (cold)

50 / 100
60 / 100

Same in both: Brazeability / Solderability 15 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale2018

2018-F vs 2018-O — frequently asked

Is 2018-F stronger than 2018-O?

Yes. 2018-F has a typical yield strength of 140 MPa (20.3 ksi) against 70 MPa (10.2 ksi) for 2018-O — about 100% more. Tensile strength is 250 MPa (36.3 ksi) vs 140 MPa (20.3 ksi).

Which condition does FabDigit quote by default, F or O?

T61 is the default 2018 condition in the FabDigit quote flow (neither F nor O). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 2018-F or 2018-O?

2018-F. Its machinability rates good (55/100) against fair (45/100) for 2018-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 2018-F and 2018-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.