Aluminum · 1435 temper comparison

1435-H22 and 1435-H26 are two conditions of the same aluminum grade, 1435: H22 (strain hardened and partially annealed, quarter hard) versus H26 (strain hardened and partially annealed, three-quarter hard). The chemistry is identical, so every difference below comes from the condition. 1435-H26 is the stronger of the two: yield strength 95 MPa (13.8 ksi) against 65 MPa (9.43 ksi) for 1435-H22, about 46% more; tensile strength follows at 115 MPa (16.7 ksi) vs 90 MPa (13.1 ksi). In exchange, 1435-H22 is the more ductile: elongation 16% versus 8% for 1435-H26, and 1435-H26 is harder (31 HB vs 24 HB). 1435-H22 runs hotter in service (150°C vs 125°C continuous).

1435-H22Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1435-H26Choose it when strength drives the design.

1435-H22 vs 1435-H26: properties

1435-H221435-H26

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

90 MPa13.1 ksi
115 MPa16.7 ksi

Yield Strength (0.2% offset)

65 MPa9.4 ksi
95 MPa13.8 ksi

Elongation at Break

16%
8%

Shear Strength

62 MPa9 ksi
76 MPa11 ksi

Fatigue Strength (Endurance Limit)

33 MPa4.8 ksi
42 MPa6.1 ksi

Hardness, Brinell

24 HB
31 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 646°C1,195 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

232 W/m·K134 BTU/hr·ft·°F
231 W/m·K133 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
125°C257 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -270°C-454 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

61.5 % IACS
61 % IACS

Electrical Resistivity

2.8×10⁻⁸ Ω·m1.1 µΩ·in
2.83×10⁻⁸ Ω·m1.11 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
36 / 100

Machinability Rating (AISI 1212 = 100 %)

33%
40%

Weldability

92 / 100
91 / 100

Formability (cold)

92 / 100
70 / 100

Same in both: Brazeability / Solderability 78 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 15%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1435

1435-H22 vs 1435-H26 — frequently asked

Is 1435-H26 stronger than 1435-H22?

Yes. 1435-H26 has a typical yield strength of 95 MPa (13.8 ksi) against 65 MPa (9.43 ksi) for 1435-H22 — about 46% more. Tensile strength is 115 MPa (16.7 ksi) vs 90 MPa (13.1 ksi).

Which condition does FabDigit quote by default, H22 or H26?

O is the default 1435 condition in the FabDigit quote flow (neither H22 nor H26). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1435-H22 or 1435-H26?

1435-H26. Its machinability rates fair (36/100) against poor (30/100) for 1435-H22.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1435-H22 and 1435-H26 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.