FabDigitFabDigit

Aluminum 1275-H111 vs 1275-H16

Aluminum · 1275 temper comparison

1275-H111 and 1275-H16 are two conditions of the same aluminum grade, 1275: H111 (slightly strain hardened) versus H16 (strain hardened, three-quarter hard). The chemistry is identical, so every difference below comes from the condition. 1275-H16 is the stronger of the two: yield strength 105 MPa (15.2 ksi) against 30 MPa (4.35 ksi) for 1275-H111, about 3.5 times as much; tensile strength follows at 115 MPa (16.7 ksi) vs 75 MPa (10.9 ksi). In exchange, 1275-H111 is the more ductile: elongation 35% versus 5% for 1275-H16, and 1275-H16 is harder (34 HB vs 21 HB). 1275-H111 runs hotter in service (150°C vs 120°C continuous).

1275-H111Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1275-H16Choose it when strength drives the design.

1275-H111 vs 1275-H16: properties

1275-H1111275-H16

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

75 MPa10.9 ksi
115 MPa16.7 ksi

Yield Strength (0.2% offset)

30 MPa4.4 ksi
105 MPa15.2 ksi

Elongation at Break

35%
5%

Shear Strength

50 MPa7.3 ksi
68 MPa9.9 ksi

Fatigue Strength (Endurance Limit)

28 MPa4.1 ksi
40 MPa5.8 ksi

Hardness, Brinell

21 HB
34 HB

Hardness, Vickers

23 HV
38 HV

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 76 GPa11 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 646°C1,195 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

232 W/m·K134 BTU/hr·ft·°F
229 W/m·K132 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
120°C248 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

61.8 % IACS
61.3 % IACS

Electrical Resistivity

2.79×10⁻⁸ Ω·m1.1 µΩ·in
2.81×10⁻⁸ Ω·m1.11 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

63 / 100
61 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.84 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

26 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

22%
32%

Weldability

93 / 100
90 / 100

Formability (cold)

94 / 100
65 / 100

Same in both: Brazeability / Solderability 80 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 210 MJ/kg90,284 BTU/lb · Embodied Carbon (primary production) 13 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 3%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1275

1275-H111 vs 1275-H16 — frequently asked

Is 1275-H16 stronger than 1275-H111?

Yes. 1275-H16 has a typical yield strength of 105 MPa (15.2 ksi) against 30 MPa (4.35 ksi) for 1275-H111 — about 3.5 times as much. Tensile strength is 115 MPa (16.7 ksi) vs 75 MPa (10.9 ksi).

Which condition does FabDigit quote by default, H111 or H16?

H14 is the default 1275 condition in the FabDigit quote flow (neither H111 nor H16). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1275-H111 or 1275-H16?

1275-H16. Its machinability rates fair (35/100) against poor (26/100) for 1275-H111.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1275-H111 and 1275-H16 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.