FabDigitFabDigit

Aluminum 1188-H111 vs 1188-H14

Aluminum · 1188 temper comparison

1188-H111 and 1188-H14 are two conditions of the same aluminum grade, 1188: H111 (slightly strain hardened) versus H14 (strain hardened, half hard). The chemistry is identical, so every difference below comes from the condition. 1188-H14 is the stronger of the two: yield strength 72 MPa (10.4 ksi) against 28 MPa (4.06 ksi) for 1188-H111, about 157% more; tensile strength follows at 90 MPa (13.1 ksi) vs 68 MPa (9.86 ksi). In exchange, 1188-H111 is the more ductile: elongation 38% versus 12% for 1188-H14, and 1188-H14 is harder (26 HB vs 19 HB). 1188-H111 runs hotter in service (150°C vs 120°C continuous).

1188-H111Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1188-H14Choose it when strength drives the design.

1188-H111 vs 1188-H14: properties

1188-H1111188-H14

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

68 MPa9.9 ksi
90 MPa13.1 ksi

Yield Strength (0.2% offset)

28 MPa4.1 ksi
72 MPa10.4 ksi

Elongation at Break

38%
12%

Shear Strength

47 MPa6.8 ksi
58 MPa8.4 ksi

Fatigue Strength (Endurance Limit)

21 MPa3 ksi
33 MPa4.8 ksi

Hardness, Brinell

19 HB
26 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 657°C1,215 °F · Liquidus Temperature 660°C1,220 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

235 W/m·K136 BTU/hr·ft·°F
232 W/m·K134 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
120°C248 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -270°C-454 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

62.3 % IACS
62 % IACS

Electrical Resistivity

2.77×10⁻⁸ Ω·m1.09 µΩ·in
2.76×10⁻⁸ Ω·m1.09 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.85 V · Corrosion Resistance 78 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

20 / 100
26 / 100

Machinability Rating (AISI 1212 = 100 %)

28%
30%

Formability (cold)

95 / 100
78 / 100

Same in both: Weldability 92 / 100 · Castability 40 / 100 · Brazeability / Solderability 80 / 100 · Polishability 90 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 215 MJ/kg92,433 BTU/lb · Embodied Carbon (primary production) 13.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 0%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1188

1188-H111 vs 1188-H14 — frequently asked

Is 1188-H14 stronger than 1188-H111?

Yes. 1188-H14 has a typical yield strength of 72 MPa (10.4 ksi) against 28 MPa (4.06 ksi) for 1188-H111 — about 157% more. Tensile strength is 90 MPa (13.1 ksi) vs 68 MPa (9.86 ksi).

Which condition does FabDigit quote by default, H111 or H14?

O is the default 1188 condition in the FabDigit quote flow (neither H111 nor H14). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 1188-H111 or 1188-H14?

1188-H14, by a small margin. Both rate poor for machinability — 26/100 against 20/100 for 1188-H111.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1188-H111 and 1188-H14 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.