FabDigitFabDigit

Aluminum 1070-H12 vs 1070-H16

Aluminum · 1070 temper comparison

1070-H12 and 1070-H16 are two conditions of the same aluminum grade, 1070: H12 (strain hardened, quarter hard) versus H16 (strain hardened, three-quarter hard). The chemistry is identical, so every difference below comes from the condition. 1070-H16 is the stronger of the two: yield strength 105 MPa (15.2 ksi) against 70 MPa (10.2 ksi) for 1070-H12, about 50% more; tensile strength follows at 120 MPa (17.4 ksi) vs 85 MPa (12.3 ksi). In exchange, 1070-H12 is the more ductile: elongation 12% versus 5% for 1070-H16, and 1070-H16 is harder (33 HB vs 25 HB). 1070-H12 runs hotter in service (120°C vs 110°C continuous).

1070-H12Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1070-H16Choose it when strength drives the design.

1070-H12 vs 1070-H16: properties

1070-H121070-H16

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

85 MPa12.3 ksi
120 MPa17.4 ksi

Yield Strength (0.2% offset)

70 MPa10.2 ksi
105 MPa15.2 ksi

Elongation at Break

12%
5%

Shear Strength

55 MPa8 ksi
70 MPa10.2 ksi

Fatigue Strength (Endurance Limit)

30 MPa4.4 ksi
40 MPa5.8 ksi

Hardness, Brinell

25 HB
33 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 646°C1,195 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

226 W/m·K131 BTU/hr·ft·°F
224 W/m·K129 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
110°C230 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -270°C-454 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

59 % IACS
58.6 % IACS

Electrical Resistivity

2.92×10⁻⁸ Ω·m1.15 µΩ·in
2.94×10⁻⁸ Ω·m1.16 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

78 / 100
77 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.84 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

37 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

45%
50%

Weldability

90 / 100
88 / 100

Formability (cold)

88 / 100
65 / 100

Same in both: Brazeability / Solderability 88 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 10%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1070

1070-H12 vs 1070-H16 — frequently asked

Is 1070-H16 stronger than 1070-H12?

Yes. 1070-H16 has a typical yield strength of 105 MPa (15.2 ksi) against 70 MPa (10.2 ksi) for 1070-H12 — about 50% more. Tensile strength is 120 MPa (17.4 ksi) vs 85 MPa (12.3 ksi).

Which condition does FabDigit quote by default, H12 or H16?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 1070-H12 or 1070-H16?

1070-H16, by a small margin. Both rate fair for machinability — 42/100 against 37/100 for 1070-H12.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1070-H12 and 1070-H16 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.