FabDigitFabDigit

Copper Alloy C69710-H02 vs C69710-M30

Copper Alloy · C69710 temper comparison

C69710-H02 and C69710-M30 are two conditions of the same copper alloy grade, C69710: H02 (half hard) versus M30 (as hot extruded). The chemistry is identical, so every difference below comes from the condition. C69710-H02 is the stronger of the two: yield strength 380 MPa (55.1 ksi) against 215 MPa (31.2 ksi) for C69710-M30, about 77% more; tensile strength follows at 550 MPa (79.8 ksi) vs 450 MPa (65.3 ksi). In exchange, C69710-M30 is the more ductile: elongation 25% versus 12% for C69710-H02, and C69710-H02 is harder (160 HB vs 120 HB).

C69710-H02Choose it when strength drives the design.

C69710-M30Choose it when the part is bent, formed or impact-loaded.

C69710-H02 vs C69710-M30: properties

C69710-H02C69710-M30

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

550 MPa79.8 ksi
450 MPa65.3 ksi

Yield Strength (0.2% offset)

380 MPa55.1 ksi
215 MPa31.2 ksi

Elongation at Break

12%
25%

Shear Strength

340 MPa49.3 ksi
300 MPa43.5 ksi

Fatigue Strength (Endurance Limit)

185 MPa26.8 ksi
165 MPa23.9 ksi

Hardness, Brinell

160 HB
120 HB

Hardness, Rockwell B

85 HRB
72 HRB

Same in both: Elastic (Young's) Modulus 103 GPa14.9 Msi · Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.34 · Reduction in Area 45% · Charpy V-Notch Impact (RT) 30 J22.1 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 8.3 g/cm³0.3 lb/in³ · Melting Point (Solidus) 821°C1,510 °F · Liquidus Temperature 916°C1,681 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 30 W/m·K17.3 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.2 µm/m·K11.2 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 6.7 % IACS · Electrical Resistivity 2.6×10⁻⁷ Ω·m10.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

85 / 100
80 / 100

Machinability Rating (AISI 1212 = 100 %)

85%
80%

Formability (cold)

25 / 100
40 / 100

Same in both: Weldability 35 / 100 · Brazeability / Solderability 75 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 60 MJ/kg25,795 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC69710

C69710-H02 vs C69710-M30 — frequently asked

Is C69710-H02 stronger than C69710-M30?

Yes. C69710-H02 has a typical yield strength of 380 MPa (55.1 ksi) against 215 MPa (31.2 ksi) for C69710-M30 — about 77% more. Tensile strength is 550 MPa (79.8 ksi) vs 450 MPa (65.3 ksi).

Which condition does FabDigit quote by default, H02 or M30?

M30 is the default C69710 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C69710-H02 or C69710-M30?

C69710-H02. Its machinability rates excellent (85/100) against very good (80/100) for C69710-M30.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C69710-H02 and C69710-M30 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.