FabDigitFabDigit

Copper Alloy C79200-H01 vs C79200-H02

Copper Alloy · C79200 temper comparison

C79200-H01 and C79200-H02 are two conditions of the same copper alloy grade, C79200: H01 (quarter hard) versus H02 (half hard). The chemistry is identical, so every difference below comes from the condition. C79200-H02 is the stronger of the two: yield strength 415 MPa (60.2 ksi) against 310 MPa (45 ksi) for C79200-H01, about 34% more; tensile strength follows at 510 MPa (74 ksi) vs 450 MPa (65.3 ksi). In exchange, C79200-H01 is the more ductile: elongation 25% versus 12% for C79200-H02, and C79200-H02 is harder (150 HB vs 130 HB).

C79200-H01Choose it when the part is bent, formed or impact-loaded.

C79200-H02Choose it when strength drives the design.

C79200-H01 vs C79200-H02: properties

C79200-H01C79200-H02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

450 MPa65.3 ksi
510 MPa74 ksi

Yield Strength (0.2% offset)

310 MPa45 ksi
415 MPa60.2 ksi

Elongation at Break

25%
12%

Reduction in Area

35%
22%

Compressive Strength

320 MPa46.4 ksi
430 MPa62.4 ksi

Shear Strength

300 MPa43.5 ksi
330 MPa47.9 ksi

Fatigue Strength (Endurance Limit)

170 MPa24.7 ksi
185 MPa26.8 ksi

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
13 J9.6 ft·lbf

Hardness, Brinell

130 HB
150 HB

Hardness, Rockwell B

70 HRB
78 HRB

Hardness, Vickers

137 HV
157 HV

Same in both: Elastic (Young's) Modulus 124 GPa18 Msi · Shear Modulus 46 GPa6.7 Msi · Bulk Modulus 121 GPa17.5 Msi · Poisson's Ratio 0.33 · Hardness, Rockwell C 8 HRC

Physical

Density and transition temperatures.

Same in both: Density 8.7 g/cm³0.31 lb/in³ · Melting Point (Solidus) 995°C1,823 °F · Liquidus Temperature 1,030°C1,886 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

200°C392 °F
190°C374 °F

Same in both: Thermal Conductivity 45 W/m·K26 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 190 J/g81.7 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9 % IACS · Electrical Resistivity 1.92×10⁻⁷ Ω·m7.56 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

70 / 100
75 / 100

Machinability Rating (AISI 1212 = 100 %)

170%
180%

Formability (cold)

55 / 100
40 / 100

Same in both: Weldability 20 / 100 · Brazeability / Solderability 60 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 68 MJ/kg29,235 BTU/lb · Embodied Carbon (primary production) 4.6 kg CO₂/kg · Embodied Water 280 L/kg33.6 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC79200

C79200-H01 vs C79200-H02 — frequently asked

Is C79200-H02 stronger than C79200-H01?

Yes. C79200-H02 has a typical yield strength of 415 MPa (60.2 ksi) against 310 MPa (45 ksi) for C79200-H01 — about 34% more. Tensile strength is 510 MPa (74 ksi) vs 450 MPa (65.3 ksi).

Which condition does FabDigit quote by default, H01 or H02?

H04 is the default C79200 condition in the FabDigit quote flow (neither H01 nor H02). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C79200-H01 or C79200-H02?

C79200-H02, by a small margin. Both rate very good for machinability — 75/100 against 70/100 for C79200-H01.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C79200-H01 and C79200-H02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.