FabDigitFabDigit

Copper Alloy C72500-H01 vs C72500-H14

Copper Alloy · C72500 temper comparison

C72500-H01 and C72500-H14 are two conditions of the same copper alloy grade, C72500: H01 (quarter hard) versus H14 (strain hardened, half hard). The chemistry is identical, so every difference below comes from the condition. C72500-H14 is the stronger of the two: yield strength 725 MPa (105 ksi) against 400 MPa (58 ksi) for C72500-H01, about 81% more; tensile strength follows at 760 MPa (110 ksi) vs 470 MPa (68.2 ksi). In exchange, C72500-H01 is the more ductile: elongation 15% versus 2% for C72500-H14, and C72500-H14 is harder (235 HV vs 150 HV). C72500-H01 runs hotter in service (175°C vs 150°C continuous).

C72500-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C72500-H14Choose it when strength drives the design.

C72500-H01 vs C72500-H14: properties

C72500-H01C72500-H14

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

470 MPa68.2 ksi
760 MPa110 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
725 MPa105 ksi

Elongation at Break

15%
2%

Shear Strength

300 MPa43.5 ksi
430 MPa62.4 ksi

Fatigue Strength (Endurance Limit)

210 MPa30.5 ksi
280 MPa40.6 ksi

Hardness, Rockwell B

66 HRB
94 HRB

Hardness, Vickers

150 HV
235 HV

Same in both: Elastic (Young's) Modulus 138 GPa20 Msi · Shear Modulus 52 GPa7.5 Msi · Bulk Modulus 138 GPa20 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.89 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,060°C1,940 °F · Liquidus Temperature 1,127°C2,061 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

175°C347 °F
150°C302 °F

Same in both: Thermal Conductivity 45 W/m·K26 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 11 % IACS · Electrical Resistivity 1.57×10⁻⁷ Ω·m6.18 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.22 V · Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
35 / 100

Formability (cold)

70 / 100
20 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 55 / 100 · Brazeability / Solderability 90 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.2 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC72500

C72500-H01 vs C72500-H14 — frequently asked

Is C72500-H14 stronger than C72500-H01?

Yes. C72500-H14 has a typical yield strength of 725 MPa (105 ksi) against 400 MPa (58 ksi) for C72500-H01 — about 81% more. Tensile strength is 760 MPa (110 ksi) vs 470 MPa (68.2 ksi).

Which condition does FabDigit quote by default, H01 or H14?

H02 is the default C72500 condition in the FabDigit quote flow (neither H01 nor H14). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C72500-H01 or C72500-H14?

C72500-H14. Its machinability rates fair (35/100) against poor (30/100) for C72500-H01.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C72500-H01 and C72500-H14 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.