FabDigitFabDigit

Copper Alloy C72200-H06 vs C72200-M20

Copper Alloy · C72200 temper comparison

C72200-H06 and C72200-M20 are two conditions of the same copper alloy grade, C72200: H06 (extra hard) versus M20 (as hot rolled). The chemistry is identical, so every difference below comes from the condition. C72200-H06 is the stronger of the two: yield strength 540 MPa (78.3 ksi) against 140 MPa (20.3 ksi) for C72200-M20, about 3.9 times as much; tensile strength follows at 585 MPa (84.8 ksi) vs 360 MPa (52.2 ksi). In exchange, C72200-M20 is the more ductile: elongation 35% versus 5% for C72200-H06, and C72200-H06 is harder (175 HB vs 74 HB). C72200-M20 runs hotter in service (320°C vs 220°C continuous).

C72200-H06Choose it when strength drives the design.

C72200-M20Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C72200-H06 vs C72200-M20: properties

C72200-H06C72200-M20

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

585 MPa84.8 ksi
360 MPa52.2 ksi

Yield Strength (0.2% offset)

540 MPa78.3 ksi
140 MPa20.3 ksi

Elongation at Break

5%
35%

Shear Strength

340 MPa49.3 ksi
240 MPa34.8 ksi

Fatigue Strength (Endurance Limit)

225 MPa32.6 ksi
145 MPa21 ksi

Hardness, Brinell

175 HB
74 HB

Hardness, Rockwell B

86 HRB
32 HRB

Same in both: Elastic (Young's) Modulus 145 GPa21 Msi · Shear Modulus 55 GPa8 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.33 · Reduction in Area 60% · Charpy V-Notch Impact (RT) 100 J73.8 ft·lbf · Hardness, Vickers 82 HV

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,130°C2,066 °F · Liquidus Temperature 1,180°C2,156 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

220°C428 °F
320°C608 °F

Same in both: Thermal Conductivity 34 W/m·K19.6 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 15.7 µm/m·K8.7 µin/in·°F · Latent Heat of Fusion 210 J/g90.3 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 5.5 % IACS · Electrical Resistivity 3.13×10⁻⁷ Ω·m12.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.24 V · Corrosion Resistance 82 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

37 / 100
30 / 100

Formability (cold)

20 / 100
80 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 80 / 100 · Brazeability / Solderability 85 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 92 MJ/kg39,553 BTU/lb · Embodied Carbon (primary production) 6.2 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC72200

C72200-H06 vs C72200-M20 — frequently asked

Is C72200-H06 stronger than C72200-M20?

Yes. C72200-H06 has a typical yield strength of 540 MPa (78.3 ksi) against 140 MPa (20.3 ksi) for C72200-M20 — about 3.9 times as much. Tensile strength is 585 MPa (84.8 ksi) vs 360 MPa (52.2 ksi).

Which condition does FabDigit quote by default, H06 or M20?

O61 is the default C72200 condition in the FabDigit quote flow (neither H06 nor M20). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C72200-H06 or C72200-M20?

C72200-H06. Its machinability rates fair (37/100) against poor (30/100) for C72200-M20.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C72200-H06 and C72200-M20 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.