C11300-H01 and C11300-H06 are two conditions of the same copper alloy grade, C11300: H01 (quarter hard) versus H06 (extra hard). The chemistry is identical, so every difference below comes from the condition. C11300-H06 is the stronger of the two: yield strength 330 MPa (47.9 ksi) against 215 MPa (31.2 ksi) for C11300-H01, about 53% more; tensile strength follows at 365 MPa (52.9 ksi) vs 275 MPa (39.9 ksi). In exchange, C11300-H01 is the more ductile: elongation 25% versus 5% for C11300-H06, and C11300-H06 is harder (105 HB vs 70 HB). C11300-H01 runs hotter in service (210°C vs 190°C continuous).

C11300-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C11300-H06Choose it when strength drives the design.

C11300-H01 vs C11300-H06: properties

C11300-H01C11300-H06

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

275 MPa39.9 ksi
365 MPa52.9 ksi

Yield Strength (0.2% offset)

215 MPa31.2 ksi
330 MPa47.9 ksi

Elongation at Break

25%
5%

Shear Strength

175 MPa25.4 ksi
205 MPa29.7 ksi

Fatigue Strength (Endurance Limit)

95 MPa13.8 ksi
120 MPa17.4 ksi

Hardness, Brinell

70 HB
105 HB

Hardness, Rockwell B

28 HRB
62 HRB

Hardness, Vickers

78 HV
115 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34 · Reduction in Area 55%

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

389 W/m·K225 BTU/hr·ft·°F
387 W/m·K224 BTU/hr·ft·°F

Max Service Temperature (continuous)

210°C410 °F
190°C374 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -250°C-418 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

99 % IACS
97.5 % IACS

Electrical Resistivity

1.74×10⁻⁸ Ω·m0.685 µΩ·in
1.77×10⁻⁸ Ω·m0.697 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.22 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
33 / 100

Formability (cold)

78 / 100
35 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 35 / 100 · Castability 35 / 100 · Brazeability / Solderability 95 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC11300

C11300-H01 vs C11300-H06 — frequently asked

Is C11300-H06 stronger than C11300-H01?

Yes. C11300-H06 has a typical yield strength of 330 MPa (47.9 ksi) against 215 MPa (31.2 ksi) for C11300-H01 — about 53% more. Tensile strength is 365 MPa (52.9 ksi) vs 275 MPa (39.9 ksi).

Which condition does FabDigit quote by default, H01 or H06?

H04 is the default C11300 condition in the FabDigit quote flow (neither H01 nor H06). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C11300-H01 or C11300-H06?

C11300-H06, by a small margin. Both rate poor for machinability — 33/100 against 28/100 for C11300-H01.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C11300-H01 and C11300-H06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.